MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

A Crombé1, M Saranathan2, A Ruet3, M Durieux1, E de Roquefeuil1, J C Ouallet4, B Brochet3, V Dousset5, T Tourdias6.   

Abstract

BACKGROUND AND
PURPOSE: In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI for the detection of gadolinium-enhancing MS lesions.
MATERIALS AND METHODS: Fifty-eight patients with MS were prospectively imaged at 3T by using both 2D-spin-echo and 3D-gradient recalled-echo T1WI in random order after the injection of gadolinium. Blinded and independent evaluation was performed by a junior and a senior reader to count gadolinium-enhancing lesions and to characterize their location, size, pattern of enhancement, and the relative contrast between enhancing lesions and the adjacent white matter. Finally, the SNR and relative contrast of gadolinium-enhancing lesions were computed for both sequences by using simulations.
RESULTS: Significantly more gadolinium-enhancing lesions were reported on 3D-gradient recalled-echo than on 2D-spin-echo (n = 59 versus n = 30 for the junior reader, P = .021; n = 77 versus n = 61 for the senior reader, P = .017). The difference between the 2 readers was significant on 2D-spin-echo (P = .044), for which images were less reproducible (κ = 0.51) than for 3D-gradient recalled-echo (κ = 0.65). Further comparisons showed that there were statistically more small lesions (<5 mm) on 3D-gradient recalled-echo than on 2D-spin-echo (P = .04), while other features were similar. Theoretic results from simulations predicted SNR and lesion contrast for 3D-gradient recalled-echo to be better than for 2D-spin-echo for visualization of small enhancing lesions and were, therefore, consistent with clinical observations.
CONCLUSIONS: At 3T, 3D-gradient recalled-echo provides a higher detection rate of gadolinium-enhancing lesions, especially those with smaller size, with a better reproducibility; this finding suggests using 3D-gradient recalled-echo to detect MS activity, with potential impact in initiation, monitoring, and optimization of therapy.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25376810      PMCID: PMC8013064          DOI: 10.3174/ajnr.A4152

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  33 in total

1.  MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain.

Authors:  M Brant-Zawadzki; G D Gillan; W R Nitz
Journal:  Radiology       Date:  1992-03       Impact factor: 11.105

2.  Standardized MR imaging protocol for multiple sclerosis: Consortium of MS Centers consensus guidelines.

Authors:  J H Simon; D Li; A Traboulsee; P K Coyle; D L Arnold; F Barkhof; J A Frank; R Grossman; D W Paty; E W Radue; J S Wolinsky
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

3.  Basic and escalating immunomodulatory treatments in multiple sclerosis: current therapeutic recommendations.

Authors:  H Wiendl; K V Toyka; P Rieckmann; R Gold; H-P Hartung; R Hohlfeld
Journal:  J Neurol       Date:  2008-10-29       Impact factor: 4.849

4.  Optimized three-dimensional fast-spin-echo MRI.

Authors:  John P Mugler
Journal:  J Magn Reson Imaging       Date:  2014-01-08       Impact factor: 4.813

Review 5.  MR imaging in multiple sclerosis: review and recommendations for current practice.

Authors:  K-O Lövblad; N Anzalone; A Dörfler; M Essig; B Hurwitz; L Kappos; S-K Lee; M Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-17       Impact factor: 3.825

6.  Optimization of magnetization-prepared 3-dimensional fluid attenuated inversion recovery imaging for lesion detection at 7 T.

Authors:  Manojkumar Saranathan; Thomas Tourdias; Adam B Kerr; Jeff D Bernstein; Geoffrey A Kerchner; May H Han; Brian K Rutt
Journal:  Invest Radiol       Date:  2014-05       Impact factor: 6.016

7.  3D MPRAGE evaluation of lesions in the posterior cranial fossa.

Authors:  F Wenz; T Hess; M V Knopp; G Weisser; S Blüml; L R Schad; H Hawighorst; G van Kaick
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

8.  Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis.

Authors:  Bastiaan Moraal; Stefan D Roosendaal; Petra J W Pouwels; Hugo Vrenken; Ronald A van Schijndel; Dominik S Meier; Charles R G Guttmann; Jeroen J G Geurts; Frederik Barkhof
Journal:  Eur Radiol       Date:  2008-05-29       Impact factor: 5.315

Review 9.  Predicting responders to therapies for multiple sclerosis.

Authors:  Jordi Río; Manuel Comabella; Xavier Montalban
Journal:  Nat Rev Neurol       Date:  2009-10       Impact factor: 42.937

10.  The Holy Grail in diagnostic neuroradiology: 3T or 3D?

Authors:  Frederik Barkhof; Petra J W Pouwels; Mike P Wattjes
Journal:  Eur Radiol       Date:  2010-12-23       Impact factor: 5.315

View more
  8 in total

Review 1.  Evidence-based guidelines: MAGNIMS consensus guidelines on the use of MRI in multiple sclerosis-clinical implementation in the diagnostic process.

Authors:  Àlex Rovira; Mike P Wattjes; Mar Tintoré; Carmen Tur; Tarek A Yousry; Maria P Sormani; Nicola De Stefano; Massimo Filippi; Cristina Auger; Maria A Rocca; Frederik Barkhof; Franz Fazekas; Ludwig Kappos; Chris Polman; David Miller; Xavier Montalban
Journal:  Nat Rev Neurol       Date:  2015-07-07       Impact factor: 42.937

2.  Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI.

Authors:  F X Aymerich; C Auger; P Alcaide-Leon; D Pareto; E Huerga; J F Corral; R Mitjana; J Sastre-Garriga; X Montalban; A Rovira
Journal:  Eur Radiol       Date:  2016-07-25       Impact factor: 5.315

3.  Deep Learning for Predicting Enhancing Lesions in Multiple Sclerosis from Noncontrast MRI.

Authors:  Ponnada A Narayana; Ivan Coronado; Sheeba J Sujit; Jerry S Wolinsky; Fred D Lublin; Refaat E Gabr
Journal:  Radiology       Date:  2019-12-17       Impact factor: 11.105

4.  Gadolinium-Enhanced Susceptibility-Weighted Imaging in Multiple Sclerosis: Optimizing the Recognition of Active Plaques for Different MR Imaging Sequences.

Authors:  L L F do Amaral; D C Fragoso; R H Nunes; I A Littig; A J da Rocha
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-07       Impact factor: 3.825

Review 5.  Diagnosis of multiple sclerosis through the lens of ultra-high-field MRI.

Authors:  Pascal Sati
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

6.  What are the true volumes of SEGA tumors? Reliability of planimetric and popular semi-automated image segmentation methods.

Authors:  Konrad Stawiski; Joanna Trelińska; Dobromiła Baranska; Iwona Dachowska; Katarzyna Kotulska; Sergiusz Jóźwiak; Wojciech Fendler; Wojciech Młynarski
Journal:  MAGMA       Date:  2017-03-20       Impact factor: 2.310

Review 7.  Imaging Markers for Monitoring Disease Activity in Multiple Sclerosis.

Authors:  Suradech Suthiphosuwan; David Kim; Aditya Bharatha; Jiwon Oh
Journal:  Curr Treat Options Neurol       Date:  2017-05       Impact factor: 3.598

8.  T1w dark blood imaging improves detection of contrast enhancing lesions in multiple sclerosis.

Authors:  Christian Thaler; Tanja Schneider; Jan Sedlacik; Daniel Kutzner; Jan-Patrick Stellmann; Christoph Heesen; Jens Fiehler; Susanne Siemonsen
Journal:  PLoS One       Date:  2017-08-10       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.