Literature DB >> 8022215

Investigation of a pulse compression technique for medical ultrasound: a simulation study.

N A Rao1.   

Abstract

Pulse compression techniques that are capable of producing a large signal-to-noise (SNR) enhancement, have been used successfully in many different fields. For medical applications, frequency-dependent attenuation in soft tissue can limit the usefulness of this method. In the paper, this issue is examined through model-simulation studies. Frequency-modulation (FM) chirp, considered in the study, is just one form of pulse coding technique. Pulse propagation effects in soft tissue are modelled as a linear zero phase filter. A method to perform simulations and estimate the effective time-bandwidth product K is outlined. K describes the SNR enhancement attainable under limitations imposed by the soft-tissue medium. An effective time-bandwidth product is evaluated as a function of soft-tissue linear attenuation coefficient alpha o, scatterer depth z and the bandwidth of the interrogating FM pulse, under realistic conditions. Results indicate that, under certain conditions, K can be significantly lower than its expected value in a non-attenuating medium. It is argued that although limitations exist, pulse compression techniques can still be used to improve resolution or increase penetrational depth. The real advantage over conventional short-pulse imaging comes from the possibility that these improvements can be accomplished without increasing the peak intensity of the interrogating pulse above any threshold levels set by possible bio-effect considerations.

Mesh:

Year:  1994        PMID: 8022215     DOI: 10.1007/bf02518916

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

Review 1.  Compilation of empirical ultrasonic properties of mammalian tissues. II.

Authors:  S A Goss; R L Johnston; F Dunn
Journal:  J Acoust Soc Am       Date:  1980-07       Impact factor: 1.840

2.  Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound.

Authors:  R E Apfel; C K Holland
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

3.  Coded excitation system for improving the penetration of real-time phased-array imaging systems.

Authors:  M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

Review 4.  What might echography learn from image science?

Authors:  C R Hill; J C Bamber; D C Crawford; H J Lowe; S Webb
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

5.  An investigation of a spread energy method for medical ultrasound systems. Part one: theory and investigation.

Authors:  Y Takeuchi
Journal:  Ultrasonics       Date:  1979-07       Impact factor: 2.890

6.  Evidence for ultrasonic finite-amplitude distortion in muscle using medical equipment.

Authors:  H C Starritt; M A Perkins; F A Duck; V F Humphrey
Journal:  J Acoust Soc Am       Date:  1985-01       Impact factor: 1.840

7.  Experimental point spread function of fm pulse imaging scheme.

Authors:  N A Rao; S Mehra; J Bridges; S Venkatraman
Journal:  Ultrason Imaging       Date:  1995-04       Impact factor: 1.578

8.  A dispersive model for the propagation of ultrasound in soft tissue.

Authors:  K V Gurumurthy; R M Arthur
Journal:  Ultrason Imaging       Date:  1982-10       Impact factor: 1.578

9.  Acoustic cavitation: a possible consequence of biomedical uses of ultrasound.

Authors:  R E Apfel
Journal:  Br J Cancer Suppl       Date:  1982-03

10.  The output of pulse-echo ultrasound equipment: a survey of powers, pressures and intensities.

Authors:  F A Duck; H C Starritt; J D Aindow; M A Perkins; A J Hawkins
Journal:  Br J Radiol       Date:  1985-10       Impact factor: 3.039

View more
  5 in total

1.  Mapping the ECG in the live rabbit heart using Ultrasound Current Source Density Imaging with coded excitation.

Authors:  Yexian Qin; Qian Li; Pier Ingram; Russell S Witte
Journal:  IEEE Netw       Date:  2012-10       Impact factor: 10.693

2.  Combining pulse compression and adaptive drive signal design to inverse filter the transducer system response and improve resolution in medical ultrasound.

Authors:  S Venkatraman; N A Rao
Journal:  Med Biol Eng Comput       Date:  1996-07       Impact factor: 2.602

3.  Optimizing frequency and pulse shape for ultrasound current source density imaging.

Authors:  Yexian Qin; Zhaohui Wang; Pier Ingram; Qian Li; Russell S Witte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

4.  Improved scatterer size estimation using backscatter coefficient measurements with coded excitation and pulse compression.

Authors:  Steven G Kanzler; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2008-06       Impact factor: 2.482

5.  Coded excitation ultrasonic needle tracking: An in vivo study.

Authors:  Wenfeng Xia; Yuval Ginsberg; Simeon J West; Daniil I Nikitichev; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.