Literature DB >> 3973223

Evidence for ultrasonic finite-amplitude distortion in muscle using medical equipment.

H C Starritt, M A Perkins, F A Duck, V F Humphrey.   

Abstract

Finite-amplitude distortion of ultrasonic waves from medical equipment has been observed to occur following transmission through calf muscle in human volunteers. Measurements were made using both dynamic pulse-echo imaging equipment and physiotherapy equipment. In both cases irradiation was carried out under operating conditions commonly used clinically. Pressure waveforms were measured at the skin surface using a broadband polyvinylidene difluoride membrane hydrophone. Using a pulsed, weakly focused 2.5-MHz beam with input peak pressure of 0.8 MPa and a pressure gain of 5.3 at the focus, the mean second harmonic peak magnitude (16 measurements) was 17 dB below the fundamental peak. A 1.1-MHz continuous wave therapy set with input peak pressure of 0.5 MPa showed mean second harmonic magnitude 23 dB below the fundamental.

Entities:  

Mesh:

Year:  1985        PMID: 3973223     DOI: 10.1121/1.392272

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  7 in total

1.  Harmonic source wavefront aberration correction for ultrasound imaging.

Authors:  Scott W Dianis; Olaf T von Ramm
Journal:  J Acoust Soc Am       Date:  2011-01       Impact factor: 1.840

Review 2.  Superharmonic Imaging for Medical Ultrasound: a Review.

Authors:  Narendra D Londhe; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-10-27       Impact factor: 4.460

3.  A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

Authors:  Lulu Deng; Meaghan A O'Reilly; Ryan M Jones; Ran An; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

4.  Investigation of a pulse compression technique for medical ultrasound: a simulation study.

Authors:  N A Rao
Journal:  Med Biol Eng Comput       Date:  1994-03       Impact factor: 2.602

5.  Nonlinear Acoustics in Ultrasound Metrology and other Selected Applications.

Authors:  Peter A Lewin
Journal:  Phys Procedia       Date:  2010-01-01

6.  Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions.

Authors:  Christian Hohl; Thorsten Schmidt; Patrick Haage; Dagmar Honnef; Marcus Blaum; Gundula Staatz; Rolf W Guenther
Journal:  Eur Radiol       Date:  2004-01-09       Impact factor: 5.315

7.  Role of clinical judgment and tissue harmonic imaging ultrasonography in diagnosis of paediatric acute appendicitis.

Authors:  Ossama Zakaria; Tamer A Sultan; Tarek H Khalil; Tamer Wahba
Journal:  World J Emerg Surg       Date:  2011-11-16       Impact factor: 5.469

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.