Mapping the ECG in the live rabbit heart using Ultrasound Current Source Density Imaging with coded excitation.

Yexian Qin1, Qian Li1, Pier Ingram1, Russell S Witte1.   

Abstract

Ultrasound current source density imaging (UCSDI) is a noninvasive technique for mapping electric current fields in 4D (space + time) with the resolution of ultrasound imaging. This approach can potentially overcome limitations of conventional electrical mapping procedures often used during treatment of cardiac arrhythmia or epilepsy. However, at physiologic currents, the detected acoustoelectric (AE) interaction signal in tissue is very weak. In this work, we evaluated coded ultrasound excitation (chirps) for improving the sensitivity of UCSDI for mapping the electrocardiogram (ECG) in a live rabbit heart preparation. Results confirmed that chirps improved detection of the AE signal by as much as 6.1 dB compared to a square pulse. We further demonstrated mapping the ECG using a clinical intracardiac catheter, 1 MHz ultrasound transducer and coded excitation. B-mode pulse echo and UCSDI revealed regions of high current flow in the heart wall during the peak of the ECG. These improvements to UCSDI are important steps towards translation of this new technology to the clinic for rapidly mapping the cardiac activation wave.

Entities:  

Keywords:  ECG; acoustoelectric; cardiac arrhythmia mapping; coded excitation chirps

Year:  2012        PMID: 25364099      PMCID: PMC4212692          DOI: 10.1109/ULTSYM.2012.0227

Source DB:  PubMed          Journal:  IEEE Netw        ISSN: 0890-8044            Impact factor:   10.693


  12 in total

1.  Four-dimensional ultrasound current source density imaging of a dipole field.

Authors:  Z H Wang; R Olafsson; P Ingram; Q Li; Y Qin; R S Witte
Journal:  Appl Phys Lett       Date:  2011-09-14       Impact factor: 3.791

2.  Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current.

Authors:  W M Jackman; X Z Wang; K J Friday; C A Roman; K P Moulton; K J Beckman; J H McClelland; N Twidale; H A Hazlitt; M I Prior
Journal:  N Engl J Med       Date:  1991-06-06       Impact factor: 91.245

Review 3.  Advances in electrical and mechanical cardiac mapping.

Authors:  Robert A Malkin; Nicolle Kramer; Benjamin Schnitz; Meera Gopalakrishnan; Amy L Curry
Journal:  Physiol Meas       Date:  2005-02       Impact factor: 2.833

Review 4.  Use of modulated excitation signals in medical ultrasound. Part I: Basic concepts and expected benefits.

Authors:  Thanassis Misaridis; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

5.  Atrial fibrillation ablation: location, location, location.

Authors:  Jeffrey J Goldberger
Journal:  J Cardiovasc Electrophysiol       Date:  2006-11-10

6.  Catheter motion during atrial ablation due to the beating heart and respiration: impact on accuracy and spatial referencing in three-dimensional mapping.

Authors:  Hanno U Klemm; Daniel Steven; Christin Johnsen; Rodolfo Ventura; Thomas Rostock; Boris Lutomsky; Tim Risius; Thomas Meinertz; Stephan Willems
Journal:  Heart Rhythm       Date:  2007-01-18       Impact factor: 6.343

7.  Coded excitation system for improving the penetration of real-time phased-array imaging systems.

Authors:  M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

8.  Investigation of a pulse compression technique for medical ultrasound: a simulation study.

Authors:  N A Rao
Journal:  Med Biol Eng Comput       Date:  1994-03       Impact factor: 2.602

9.  3D current source density imaging based on the acoustoelectric effect: a simulation study using unipolar pulses.

Authors:  Renhuan Yang; Xu Li; Jun Liu; Bin He
Journal:  Phys Med Biol       Date:  2011-05-31       Impact factor: 3.609

10.  Cardiac activation mapping using ultrasound current source density imaging (UCSDI).

Authors:  Ragnar Olafsson; Russell S Witte; Congxian Jia; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

View more
  2 in total

1.  High resolution transcranial acoustoelectric imaging of current densities from a directional deep brain stimulator.

Authors:  Chet Preston; Alexander M Alvarez; Andres Barragan; Jennifer Becker; Willard S Kasoff; Russell S Witte
Journal:  J Neural Eng       Date:  2020-02-27       Impact factor: 5.379

2.  Biological current source imaging method based on acoustoelectric effect: A systematic review.

Authors:  Hao Zhang; Minpeng Xu; Miao Liu; Xizi Song; Feng He; Shanguang Chen; Dong Ming
Journal:  Front Neurosci       Date:  2022-07-18       Impact factor: 5.152

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.