Literature DB >> 8006738

Bite forces in patients treated for mandibular angle fractures: implications for fixation recommendations.

G S Tate1, E Ellis, G Throckmorton.   

Abstract

Voluntary bite forces were recorded at varying periods in 35 males treated with rigid internal fixation for fractures of the mandibular angle. Bite forces were also obtained in 29 male controls for comparison. It was found that molar bite forces in patients were significantly less than in controls for several weeks after surgery. Further, molar bite forces on the side of the fracture were significantly less than on the nonfractured side. The results of this study indicate that recommendations for the amount of fixation required for a given fracture may be reduced.

Entities:  

Mesh:

Year:  1994        PMID: 8006738     DOI: 10.1016/0278-2391(94)90489-8

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  29 in total

1.  Role of 1.5 mm microplates in treatment of symphyseal fracture of mandible: A stress analysis based comparative study.

Authors:  Syed S Ahmed; Siddharth Bhardwaj; Md Kalim Ansari; Omar Farooq; Abid Ali Khan
Journal:  J Oral Biol Craniofac Res       Date:  2017-04-14

2.  Evaluation of in vitro resistance of different 2.0-mm titanium plates on the mandibular angle sectioning.

Authors:  Marco Aurélio Kenichi Yamaji; Patrício José de Oliveira Neto; Michel de Campos Ribeiro; Lucas Cavalieri Pereira; Márcio de Morais; Cássio Edvard Sverzut; Alexandre Elias Trivellato
Journal:  Oral Maxillofac Surg       Date:  2015-03

3.  Electromyographic analysis of anterior temporalis and superficial masseter muscles in mandibular angle fractures--a pilot study.

Authors:  Saurab Bither; Uma Mahindra; Rajshekhar Halli; Makarand Bakshi; Yogesh Kini; Mahendra Shende; Rupika Bither
Journal:  Oral Maxillofac Surg       Date:  2012-01-17

Review 4.  Mandible Fractures.

Authors:  Brent B Pickrell; Arman T Serebrakian; Renata S Maricevich
Journal:  Semin Plast Surg       Date:  2017-05       Impact factor: 2.314

5.  Comparative Evaluation between Single Noncompression Miniplate and Two Noncompression Miniplates in the Treatment of Mandibular Angle Fractures.

Authors:  Shubhamoy Mondal; Gaurav Singh; Madan Mishra; Amit Gaur; Abhinav Srivastava
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2018-04-12

6.  Assessment of masticatory function using bite force measurements in patients treated for mandibular fractures.

Authors:  Deborah Sybil; K Gopalkrishnan
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-09-26

7.  Bio-resorbable plates as effective implant in paediatric mandibular fracture.

Authors:  Geeta Singh; Shadab Mohammad; R K Chak; Norden Lepcha; Nimisha Singh; Laxman R Malkunje
Journal:  J Maxillofac Oral Surg       Date:  2011-12-28

8.  Bite force measurement in mandibular parasymphyseal fractures: a preliminary clinical study.

Authors:  Rajesh Kshirsagar; Nitin Jaggi; Rajshekhar Halli
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2011-12

9.  [Load resistance of mandibular angle fracturs treated with a miniplate osteosynthesis].

Authors:  K L Gerlach; A Schwarz
Journal:  Mund Kiefer Gesichtschir       Date:  2003-07-03

10.  Biomechanical evaluation of plating techniques for fixing mandibular angle fractures: the introduction of a new 3D plate approach.

Authors:  Evagelos F Kalfarentzos; Despoina Deligianni; Georgios Mitros; Minos Tyllianakis
Journal:  Oral Maxillofac Surg       Date:  2009-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.