Literature DB >> 23205177

Bite force measurement in mandibular parasymphyseal fractures: a preliminary clinical study.

Rajesh Kshirsagar1, Nitin Jaggi, Rajshekhar Halli.   

Abstract

We measured the amount of bite force generated by patients treated for parasymphyseal fractures of the mandible by open reduction and internal fixation at various predetermined time intervals. Sixty volunteers ranging from 18 to 60 years old were selected as the control group. All measurements were made on a bite force measurement device with the head in an upright position and in an unsupported natural position. Bite forces were measured at the incisor and right and left molar regions. These bite forces were compared with six patients with isolated mandibular unilateral parasymphyseal fractures. All patients were operated using open reduction and internal fixation using two miniplates at the fracture site. In the volunteer group, bite forces ranged from 22 to 50 kg in the molar region and 3 to 27 kg in the incisor region. Mean adult healthy values (male and female) in the molar region were 36 kg and in the incisor region, 15 kg. In mandibular parasymphyseal fractures, incisor bite forces were reduced significantly when compared with the control group in the first 2 postoperative weeks and regained significantly thereafter till 4 to 6 weeks. Bite forces in the molar region took ~6 to 12 weeks to regain maximum bite forces when compared with the volunteer group. Restoration of functional bite forces was evident by 6 to 8 weeks. However, the restoration of maximum bite forces may require up to 12 weeks in parasymphyseal fractures.

Entities:  

Keywords:  Bite force; functional bite force; jaw fracture; parasymphyseal fracture

Year:  2011        PMID: 23205177      PMCID: PMC3314259          DOI: 10.1055/s-0031-1293521

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  7 in total

1.  Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to Champy.

Authors:  K L Gerlach; A Schwarz
Journal:  Int J Oral Maxillofac Surg       Date:  2002-08       Impact factor: 2.789

2.  [On the stable osteosynthesis in mandibular fractures].

Authors:  H G Luhr
Journal:  Dtsch Zahnarztl Z       Date:  1968-07

3.  The effects of zygomatic complex fracture on masseteric muscle force.

Authors:  F Dal Santo; E Ellis; G S Throckmorton
Journal:  J Oral Maxillofac Surg       Date:  1992-08       Impact factor: 1.895

4.  Effects of local anesthesia on bite force generation and electromyographic activity.

Authors:  T J Teenier; G S Throckmorton; E Ellis
Journal:  J Oral Maxillofac Surg       Date:  1991-04       Impact factor: 1.895

5.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02

6.  A preliminary study of maximum voluntary bite force and jaw muscle efficiency in pre-orthognathic surgery patients.

Authors:  J S Dean; G S Throckmorton; E Ellis; D P Sinn
Journal:  J Oral Maxillofac Surg       Date:  1992-12       Impact factor: 1.895

7.  Bite forces in patients treated for mandibular angle fractures: implications for fixation recommendations.

Authors:  G S Tate; E Ellis; G Throckmorton
Journal:  J Oral Maxillofac Surg       Date:  1994-07       Impact factor: 1.895

  7 in total
  6 in total

1.  Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading.

Authors:  Sarah C Woodford; Dale L Robinson; Cornelia Edelmann; Albert Mehl; Oliver Röhrle; Peter Vee Sin Lee; David C Ackland
Journal:  Ann Biomed Eng       Date:  2021-01-06       Impact factor: 3.934

2.  A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation.

Authors:  Syed Sayeed Ahmed; Sajjad Abdur Rehman; Md Kalim Ansari; Abid Ali Khan; Omar Farooq; Arshad Hafeez Khan
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

3.  Is "Bite force" a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?

Authors:  Shital Patel; Kruna Bhimani; Roma Narsingyani; Zenish Bhatti; Rajan Savani
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-09

4.  Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture.

Authors:  Magdy Mohamed Zaky; Nabila Ali Fayed; Mohamed Farid Shehab
Journal:  Oral Maxillofac Surg       Date:  2019-11-12

Review 5.  Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis.

Authors:  José Cristiano Ramos Glória; Ighor Andrade Fernandes; Esmeralda Maria da Silveira; Glaciele Maria de Souza; Ricardo Lopes Rocha; Endi Lanza Galvão; Saulo Gabriel Moreira Falci
Journal:  Int Arch Otorhinolaryngol       Date:  2017-07-14

Review 6.  Bite Forces and Their Measurement in Dogs and Cats.

Authors:  Se Eun Kim; Boaz Arzi; Tanya C Garcia; Frank J M Verstraete
Journal:  Front Vet Sci       Date:  2018-04-13
  6 in total