Assessment of cardiac output from noninvasive determination of arterial pressure profile in subjects at rest.

G Antonutto1, M Girardis, D Tuniz, E Petri, C Capelli.   

Abstract

The stroke volume of the left ventricle (SV) was calculated from noninvasive recordings of the arterial pressure using a finger photoplethysmograph and compared to the values obtained by pulsed Doppler echocardiography (PDE). A group of 19 healthy men and 12 women [mean ages: 20.8 (SD 1.6) and 22.2 (SD 1.6) years respectively] were studied at rest in the supine position. The ratio of the area below the ejection phase of the arterial pressure wave (A(s)) to SV, as obtained by PDE, yielded a "calibration factor" dimensionally equal to the hydraulic impedance of the system (Zao = A(s).SV-1). The Zao amounted on average to 0.062 (SD 0.018) mmHg.s.cm-3 for the men and to 0.104 (SD 0.024) mmHg.s.cm-3 for the women. The Zao was also estimated from the equation: Zao = a.(d + b.HR + c.PP + e.MAP)-1, where HR was the heart rate, PP the pulse pressure, MAP the mean arterial pressure and the coefficients of the equation were obtained by an iterating statistical package. The value of Zao thus obtained allowed the calculation of SV from measurements derived from the photoplethysmograph only. The mean percentage error between the SV thus obtained and those experimentally determined by PDE amounted to 14.8 and 15.6 for the men and the women, respectively. The error of the estimate was reduced to 12.3 and to 11.1, respectively, if the factor Zao, experimentally obtained from a given heart beat, was subsequently applied to other beats to obtain SV from the A(s) measurement in the same subject.

Entities:  

Mesh:

Year:  1994        PMID: 8001527     DOI: 10.1007/BF01094786

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  16 in total

1.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure.

Authors:  B P Imholz; J J Settels; A H van der Meiracker; K H Wesseling; W Wieling
Journal:  Cardiovasc Res       Date:  1990-03       Impact factor: 10.787

3.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

Review 4.  Continuous cardiac output derived from the aortic pressure waveform: a review of current methods.

Authors:  W W Nichols
Journal:  Biomed Eng       Date:  1973-09

5.  Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger.

Authors:  K H Wesseling; J J Settels; G M van der Hoeven; J A Nijboer; M W Butijn; J C Dorlas
Journal:  Cardiovasc Res       Date:  1985-03       Impact factor: 10.787

6.  Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre.

Authors:  B P Imholz; G A van Montfrans; J J Settels; G M van der Hoeven; J M Karemaker; W Wieling
Journal:  Cardiovasc Res       Date:  1988-06       Impact factor: 10.787

7.  Clinical assessment of cardiac output.

Authors:  J Conway
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

Review 8.  Doppler ultrasonic measurement of cardiac output: reproducibility and validation.

Authors:  A J Coats
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

9.  The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1985       Impact factor: 2.712

10.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01
View more
  6 in total

Review 1.  Cardiovascular deconditioning in microgravity: some possible countermeasures.

Authors:  G Antonutto; P E di Prampero
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

2.  Effects of the muscle pump and body posture on cardiovascular responses during recovery from cycle exercise.

Authors:  Tatsuhisa Takahashi; Junichiro Hayano; Akiyoshi Okada; Tadashi Saitoh; Akira Kamiya
Journal:  Eur J Appl Physiol       Date:  2005-06-01       Impact factor: 3.078

Review 3.  A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stress.

Authors:  Jasper Truijen; Morten Bundgaard-Nielsen; Johannes J van Lieshout
Journal:  Eur J Appl Physiol       Date:  2010-01-07       Impact factor: 3.078

4.  Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

Authors:  G Antonutto; M Girardis; D Tuniz; P E di Prampero
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

5.  Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound.

Authors:  Johannes J van Lieshout; Karin Toska; Erik Jan van Lieshout; Morten Eriksen; Lars Walløe; Karel H Wesseling
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

6.  The Effect of Lower-Body Positive Pressure on the Cardiorespiratory Response at Rest and during Submaximal Running Exercise.

Authors:  Frédéric Stucky; Jean-Marc Vesin; Bengt Kayser; Barbara Uva
Journal:  Front Physiol       Date:  2018-01-30       Impact factor: 4.566