Tissue reactions towards titanium implants inserted in growing jaws. A histological study in the pig.

L Sennerby1, J Odman, U Lekholm, B Thilander.   

Abstract

In this investigation, the tissue reactions towards titanium implants inserted in growing jaws of pigs were studied by means of histology. At the age of 12 weeks, 5 test pigs each received 4 Brånemark System titanium implants (fixtures). The fixtures were inserted immediately after extraction of the mesial root of the second deciduous premolar (P2) and the deciduous canine (C) on one side of the mandible and the mesial root of the first deciduous premolar (P1) on the other side. The fourth implant was placed after extraction of the deciduous lateral incisor (L) on one side in the upper jaw. Furthermore, 1 pig in which no extractions or fixture installations were performed served as a control. All pigs were followed for 165 days with clinical, radiographic and biometric examinations, the results of which have been previously presented. In this study, 10-microns-thick ground sections were produced for histology after the jaws had been fixed by immersion in formalin and further processed and embedded in plastic resin. Six of the fixtures originally inserted were lost during the experimental period, and the remaining implants were found to be involved with mineralized bone to varying degrees. Regarding the fixture-to-teeth relationship, it was found that, in the premolar region of the lower jaw, the teeth were positioned superior to and buccally angulated in relation to the fixtures. In the upper jaw, the implants were positioned below the adjacent teeth but centrally in the alveolar process. Tooth germs adjacent to the fixture had a displaced eruption path, buccally or lingually to the fixture. If the bud developed in close contact with the fixture, a changed morphology of the germ could be observed.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8218745     DOI: 10.1034/j.1600-0501.1993.040202.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  [Endosseous titanium implants as orthodontic anchoring elements. Experimental studies and clinical application].

Authors:  H Wehrbein
Journal:  Fortschr Kieferorthop       Date:  1994-10

Review 2.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

3.  The minipig intraoral dental implant model: A systematic review and meta-analysis.

Authors:  Marta Liliana Musskopf; Amanda Finger Stadler; Ulf Me Wikesjö; Cristiano Susin
Journal:  PLoS One       Date:  2022-02-28       Impact factor: 3.240

4.  Prosthodontic management of hypohidrotic ectodermal dysplasia with anodontia: a case report in pediatric patient and review of literature.

Authors:  R Ladda; Sa Gangadhar; Vo Kasat; Aj Bhandari
Journal:  Ann Med Health Sci Res       Date:  2013-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.