Single lead atrial synchronous ventricular pacing: a dream come true.

G E Antonioli1.   

Abstract

Single lead, atrial synchronous pacing systems were developed in the late 1970s. Clinical experience has demonstrated the need to position the "floating" atrial electrode in the mid-to-high right atrium and the need for a specially designed pulse generator (with very high atrial sensitivity) to provide a high quality and amplitude atrial electrogram for consistent sensing. A 12-year experience with different electrode configurations, from the first unipolar designed in 1980 to the most recent atrial bipolar electrodes, has confirmed the validity of the original concept and the long-term reliability of the single lead atrial synchronous pacing system, which can reliably produce long-term atrial sensing and ventricular stimulation in the presence of normal sinoatrial function.

Entities:  

Mesh:

Year:  1994        PMID: 7991425     DOI: 10.1111/j.1540-8159.1994.tb01519.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

1.  VDD pacemaker replacement is safe and reliable independently of the previously implanted lead: a prospective and controlled study.

Authors:  Alessandro Fabiani; Antonio Burali; Enrico Manfredini; Giorgio Corbucci; Leonardo Bolognese; S Serge Barold
Journal:  J Interv Card Electrophysiol       Date:  2006-03       Impact factor: 1.900

Review 2.  "Two for the Price of One": A Single-Lead Implantable Cardioverter-Defibrillator System with a Floating Atrial Dipole.

Authors:  Nicole E Worden; Musab Alqasrawi; Siva M Krothapalli; Alexander Mazur
Journal:  J Atr Fibrillation       Date:  2016-04-30

Review 3.  Digital technology in cardiac pacing: methods for morphology analysis of sensed endocavitary signals.

Authors:  Luigi Padeletti; Antonio Michelucci; Gerd Fröhlig; Giorgio Corbucci; Geeske van Oort; Serge S Barold
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

4.  Acute evaluation of a preformed single-pass VDD/DDD pacing lead.

Authors:  M S Hazday; D Mendelson; R R Brownlee
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

Review 5.  The current status of single lead dual chamber sensing and pacing.

Authors:  H F Tse; C P Lau
Journal:  J Interv Card Electrophysiol       Date:  1998-09       Impact factor: 1.900

6.  The impact of the distance between the atrial electrode and the atrial wall on atrial undersensing in patients with VDD pacemakers: long-term follow-up.

Authors:  Timucin Altin; Muharrem Guldal; Basar Candemir; Cegerhun Polat; Aydan O Ozdemir; Cansin Tulunay; Cagdas Ozdol; Omer Akyurek; Remzi Karaoguz; Cetin Erol
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468