Literature DB >> 7890844

Determination of scan delay time in spiral CT-angiography: utility of a test bolus injection.

L van Hoe1, G Marchal, A L Baert, S Gryspeerdt, L Mertens.   

Abstract

OBJECTIVE: The usefulness of a test bolus of contrast medium for predicting the optimal scan delay time in spiral CT-angiography (CTA) was determined.
MATERIALS AND METHODS: Two axial single level CT studies were performed at the level of the pancreas in 20 patients, first after injection of a 12 ml "test" bolus, second after administration of a 90 ml bolus. The time interval between the start of the test bolus injection and peak aortic enhancement (T-peak) was measured and compared with the time required to reach a 50, 100, and 150 HU level of aortic enhancement after 90 ml bolus injection.
RESULTS: The time required to reach 50, 100, and 150 HU enhancement during the 90 ml bolus was largely variable (mean SD 4.9 s). The T-peak varied between 11 and 32 s (mean 20, SD 6.1 s). There was a strong correlation between the T-peak and the time to the different levels of enhancement during the 90 ml bolus (R2 > or = 0.83). The mean time to 50, 100, and 150 HU enhancement was T-peak -3.3 s (SD 2.5 s), T-peak -1.2 s (SD 2.4 s), and T-peak + 1.3 s (SD 2.4 s).
CONCLUSION: The injection of a test bolus improves the timing of a spiral CTA acquisition.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7890844     DOI: 10.1097/00004728-199503000-00009

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  14 in total

1.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

Review 2.  Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  Assessment of accuracy of renal artery stenosis grading in helical CT angiography using maximum intensity projections.

Authors:  L Van Hoe; D Vandermeulen; S Gryspeerdt; L Mertens; A L Baert; P Suetens; G Marchal; L Stockx
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

5.  Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

Authors:  Wen Jie Yang; Ke Min Chen; Bo Liu; Li Fang Pang; Huan Zhang; Zi Lai Pan; Fu Hua Yan
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

Review 6.  Invited article: helical/spiral CT scanning: a pediatric radiology perspective.

Authors:  K S White
Journal:  Pediatr Radiol       Date:  1996

7.  Late-arterial and portal-venous phase imaging of the liver with a multislice CT scanner in patients without circulatory disturbances: automatic bolus tracking or empirical scan delay?

Authors:  Shigeki Itoh; Mitsuru Ikeda; Masataka Achiwa; Hiroko Satake; Shingo Iwano; Takeo Ishigaki
Journal:  Eur Radiol       Date:  2004-04-06       Impact factor: 5.315

8.  Adaptive Bolus Chasing Computed Tomography Angiography: Control Scheme and Experimental Results.

Authors:  Zhijun Cai; Colbin Erdahl; Kai Zeng; Tom Potts; Melhem Sharafuddin; Osama Saba; Ge Wang; Er-Wei Bai
Journal:  Biomed Signal Process Control       Date:  2008-10       Impact factor: 3.880

9.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

10.  Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Acad Radiol       Date:  2018-08-30       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.