Literature DB >> 7872261

The value of plasma calibrants in correcting coagulometer effects on international normalized ratios. An international multicenter study.

L Poller1, D A Triplett, J Hirsh, J Carroll, K Clarke.   

Abstract

A study of lyophilized plasma calibrants in correcting for coagulometer effects on International Normalized Ratios (INR) has been conducted in an international survey. Prothrombin times were performed with the calibrants on 2 "common" thromboplastins and in-house thromboplastins in 3 brands of coagulometer at 37 centers. The International Sensitivity Indices (ISI) of 95 local systems with the calibrants were derived. The "true" INR of 10 test plasmas from warfarin-treated patients were established centrally using thromboplastin International Reference Preparations (IRP). International Normalized Ratios of these plasmas for each center were calculated using both the manufacturers' stated and the local ISI. The mean deviation of the 95 systems from the "true" INR of the warfarin plasmas was +14.4% with the manufacturers' ISI, but reduced to +1.04% with the local ISI. Local ISI determination with the calibrants avoids many of the difficulties of conventional thromboplastin calibrations. Plasmas from patients on warfarin and parallel manual PT with thromboplastin IRP are not required.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7872261     DOI: 10.1093/ajcp/103.3.358

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  7 in total

1.  Screening INR deviation of local prothrombin time systems.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1998-05       Impact factor: 3.411

2.  Accuracy and precision of the TAS analyser for near-patient INR testing by non-pathology staff in the community.

Authors:  P G Cachia; E McGregor; S Adlakha; P Davey; B M Goudie
Journal:  J Clin Pathol       Date:  1998-01       Impact factor: 3.411

3.  Field study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.

Authors:  A M van den Besselaar
Journal:  J Clin Pathol       Date:  1997-05       Impact factor: 3.411

4.  The effects of freeze drying and freeze drying additives on the prothrombin time and the international sensitivity index.

Authors:  L Poller; M Keown; S A Shepherd; C R Shiach; S Tabeart
Journal:  J Clin Pathol       Date:  1999-10       Impact factor: 3.411

5.  Evaluation of the Steelex M600H coagulometer prothrombin time-international normalized ratio assay with Steelex test reagents.

Authors:  Yasemin U Budak; Kağan Huysal; Murat Polat; Gülsevil Tarakçi; Hakan Uçar
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

Review 6.  Pharmacology of anticoagulants used in the treatment of venous thromboembolism.

Authors:  Edith A Nutescu; Allison Burnett; John Fanikos; Sarah Spinler; Ann Wittkowsky
Journal:  J Thromb Thrombolysis       Date:  2016-01       Impact factor: 2.300

7.  Erratum to: Pharmacology of anticoagulants used in the treatment of venous thromboembolism.

Authors:  Edith A Nutescu; Allison Burnett; John Fanikos; Sarah Spinler; Ann Wittkowsky
Journal:  J Thromb Thrombolysis       Date:  2016-08       Impact factor: 2.300

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.