Literature DB >> 9215117

Field study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.

A M van den Besselaar1.   

Abstract

AIM: To assess the effect of a lyophilised calibrant plasma procedure on the international normalised ratio (INR) and its interlaboratory variation.
METHODS: INR equivalent values were assigned to five lyophilised plasmas (one from normal donors and four from coumarin treated patients) by a reference laboratory using three calibrated thromboplastin reagents. The calibrant plasmas and five artificial control blood specimens were mailed to 44 Dutch laboratories for prothrombin time (PT) determination. The assigned INR values were used to calculate calibration lines for each participant laboratory. The calibration lines were then used to translate the PT of the control specimens to INR.
RESULTS: For all lyophilised plasmas and control blood samples, there were significant differences between INR values determined with the three thromboplastin reagents. These differences could not be explained by inaccuracy of the international sensitivity index or mean normal PT of the reagents and must, therefore, have been induced by the preparation procedures for the lyophilised plasmas and control blood samples. The interlaboratory variation of the INR obtained with the calibrant plasma procedure had a coefficient of variation (CV) ranging between 2.1% and 7.3% and tended to be lower than the interlaboratory variation found with the usual methods (3.0-12.2% CV). There was a good agreement between the mean INRs obtained with the calibrant procedure and those obtained using the normal methods.
CONCLUSIONS: The present study highlights the limitations of some lyophilised plasmas and control blood samples. It is not possible to assign a single INR value to each of these lyophilised plasmas and control specimens that is valid for all thromboplastin reagents. Nevertheless, by using reagent specific INR equivalent values for the calibrant plasma procedure, the interlaboratory variation could be reduced.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9215117      PMCID: PMC499936          DOI: 10.1136/jcp.50.5.371

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  17 in total

1.  A simplified thromboplastin calibration procedure for standardization of anticoagulant control.

Authors:  E A Loeliger; L P VAN Halem-Visser
Journal:  Thromb Diath Haemorrh       Date:  1975-04-30

2.  Reversible prothrombin time prolongation after plasma storage on dry ice.

Authors:  E A Plumhoff; P K Fisher; E J Bowie; W L Nichols
Journal:  Thromb Haemost       Date:  1992-08-03       Impact factor: 5.249

3.  Artificial prolongation of the prothrombin time of lyophilized plasma induced by transportation with solid carbon dioxide.

Authors:  R Vis; A M van den Besselaar; E Witteveen; J Meeuwisse-Braun; H Schaefer-van Mansfeld
Journal:  Thromb Haemost       Date:  1992-06-01       Impact factor: 5.249

4.  A simplified procedure for thromboplastin calibration--the usefulness of lyophilized plasmas assessed in a collaborative study.

Authors:  A Tripodi; V Chantarangkul; C Manotti; M Poggi; M Braga; B Akkawat; P Bucciarelli; P M Mannucci
Journal:  Thromb Haemost       Date:  1996-02       Impact factor: 5.249

5.  The preparation of control blood for external quality assessment programs in oral anticoagulant control.

Authors:  C A van Dijk-Wierda; L P van Halem-Visser; R van Der Hoeff-van Halem; E A Loeliger
Journal:  Thromb Haemost       Date:  1978-02-28       Impact factor: 5.249

6.  Studies on the procurement of blood coagulation factor VIII. In vivo studies on blood components prepared in half-strength citrate anticoagulant.

Authors:  B Griffin; K Bell; C Prowse
Journal:  Vox Sang       Date:  1988       Impact factor: 2.144

7.  Multi-center study of replacement of the international reference preparation for thromboplastin, rabbit, plain.

Authors:  A M van den Besselaar
Journal:  Thromb Haemost       Date:  1993-11-15       Impact factor: 5.249

8.  Coagulation quality control surveys in France.

Authors:  A F Goguel; L L Houbouyan; J H Roussi
Journal:  Scand J Haematol Suppl       Date:  1980

9.  Quality control of prothrombin time determinations in the Netherlands.

Authors:  C A van Dijk-Wierda; A M van den Besselaar; E A Loeliger
Journal:  Scand J Haematol Suppl       Date:  1980

10.  Proficiency testing and standardization of prothrombin time: effect of thromboplastin, instrumentation, and plasma.

Authors:  A M van den Besselaar; B L Evatt; D R Brogan; D A Triplett
Journal:  Am J Clin Pathol       Date:  1984-12       Impact factor: 2.493

View more
  1 in total

1.  Photodynamic treatment of pooled coumarin plasma for external quality assessment of the prothrombin time.

Authors:  A M van den Besselaar; A C Moor
Journal:  J Clin Pathol       Date:  2000-06       Impact factor: 3.411