Literature DB >> 7845810

Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database.

H J Smith1, N E Fearnot, C L Byrd, B L Wilkoff, C J Love, T D Sellers.   

Abstract

From December 1988 to April 1994, the extraction of 2,195 intravascular pacing leads from 1,299 patients was attempted at 193 centers. Indications were: infection (54%, including 10% septicemia), pacemaker reoperation with removal of nonfunctional or incompatible leads (40%), and other causes (6%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, via the femoral vein using snares, retrieval baskets, and sheaths, or via both approaches. Leads had been implanted for 0.2 months to 24 years (mean 56 months). At the conclusion of the intravascular procedure, 86.8% of the leads were completely removed, 7.5% were partially removed, and 5.7% were not removed. For physicians performing their first case, 12% of leads were not removed; for physicians who had performed more than 10 cases, only 2% of leads were not removed. Of the 189 leads where extraction attempts had previously failed, 75.1% were completely removed, 14.8% were partially removed, and 10.1% were not removed. Scar tissue increased in severity with implant duration, was a complicating factor, and was the main cause of failure to remove leads. Use of the femoral approach increased with implant duration (5% of leads implanted 12 months or less, 11% of leads 13 months to 3 years, 20% of leads 4-7 years, and 31% of leads 8-24 years), primarily because of increasingly abundant scarring and prior lead damage. Fatal and near fatal complications occurred in 2.5%, including 8 (0.6%) deaths (3 hemopericardium/tamponade, 1 hemothorax, 3 pulmonary embolus, 1 stroke).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7845810     DOI: 10.1111/j.1540-8159.1994.tb03792.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  44 in total

1.  Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system.

Authors:  V P Vassilikos; T N Maounis; J Chiladakis; D V Cokkinos; A S Manolis
Journal:  J Interv Card Electrophysiol       Date:  1999-10       Impact factor: 1.900

2.  Exchange of pacing or defibrillator leads following laser sheath extraction of non-functional leads in patients with ipsilateral obstructed venous access.

Authors:  F A Bracke; L M van Gelder; N Sreeram; A Meijer
Journal:  Heart       Date:  2000-06       Impact factor: 5.994

Review 3.  Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?

Authors:  F A Bracke; A Meijer; L M van Gelder
Journal:  Heart       Date:  2001-03       Impact factor: 5.994

4.  Cardiac lead extraction with a novel locking stylet.

Authors:  C Kennergren; R H Schaerf; T D Sellers; B L Wilkoff; C L Byrd; G F Tyres; S Coe; C W Coates; C Reiser
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

Review 5.  Advances in device lead extraction.

Authors:  C L Byrd
Journal:  Curr Cardiol Rep       Date:  2001-07       Impact factor: 2.931

6.  Implantable cardioverter-defibrillator lead extraction by conventional traction and counter-traction technique.

Authors:  Jong Sung Park; Hui-Nam Pak; Moon-Hyoung Lee; Sung Soon Kim; Boyoung Joung
Journal:  Korean Circ J       Date:  2011-03-31       Impact factor: 3.243

7.  Local symptoms at the site of pacemaker implantation indicate latent systemic infection.

Authors:  D Klug; F Wallet; D Lacroix; C Marquié; C Kouakam; S Kacet; R Courcol
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

8.  Arteriovenous fistula following pacemaker lead removal: CT diagnosis.

Authors:  Preet Kang; Diego B Nunez
Journal:  Emerg Radiol       Date:  2003-03-26

Review 9.  [Percutaneous lead extraction. Complications and their management].

Authors:  Heiko Burger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-12

Review 10.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

View more