Literature DB >> 11179258

Pacemaker lead complications: when is extraction appropriate and what can we learn from published data?

F A Bracke1, A Meijer, L M van Gelder.   

Abstract

Mesh:

Year:  2001        PMID: 11179258      PMCID: PMC1729652          DOI: 10.1136/heart.85.3.254

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


× No keyword cloud information.
  53 in total

Review 1.  Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty.

Authors:  C J Love; B L Wilkoff; C L Byrd; P H Belott; J A Brinker; N E Fearnot; R A Friedman; S Furman; L B Goode; D L Hayes; D T Kawanishi; V Parsonnet; C Reiser; H J Van Zandt
Journal:  Pacing Clin Electrophysiol       Date:  2000-04       Impact factor: 1.976

2.  Exchange of pacing or defibrillator leads following laser sheath extraction of non-functional leads in patients with ipsilateral obstructed venous access.

Authors:  F A Bracke; L M van Gelder; N Sreeram; A Meijer
Journal:  Heart       Date:  2000-06       Impact factor: 5.994

3.  Venous thrombosis and permanent cardiac pacing.

Authors:  S A Friedman; N Berger; M M Cerruti; J Kosmoski
Journal:  Am Heart J       Date:  1973-04       Impact factor: 4.749

4.  [Phlebographic and clinical early and late findings in transvenously implanted pacemaker electrodes].

Authors:  E Marx; H D Schulte; J Balau; K A Buysch
Journal:  Z Kreislaufforsch       Date:  1972-02

5.  [Thrombosis of the vena subclavia following transvenous pacemaker implantation].

Authors:  J Balu; K H Buysch; E Marx; A Seling; H Knieriem
Journal:  Radiologe       Date:  1971-02       Impact factor: 0.635

6.  Long-term outcome of patients with multiple (> or = 3) noninfected transvenous leads: a clinical and echocardiographic study.

Authors:  C C de Cock; M Vinkers; L C Van Campe; P M Verhorst; C A Visser
Journal:  Pacing Clin Electrophysiol       Date:  2000-04       Impact factor: 1.976

7.  Functionless retained pacing leads in the cardiovascular system. A complication of pacemaker treatment.

Authors:  F Zerbe; A Ponizyński; W Dyszkiewicz; A Ziemiański; T Dziegielewski; H Krug
Journal:  Br Heart J       Date:  1985-07

8.  Asymptomatic pulmonary embolism following pacemaker implantation.

Authors:  W Seeger; K Scherer
Journal:  Pacing Clin Electrophysiol       Date:  1986-03       Impact factor: 1.976

9.  Cerebral embolism due to left ventricular pacemaker lead: removal with cardiopulmonary bypass.

Authors:  A Liebold; H Aebert; M Muscholl; D E Birnbaum
Journal:  Pacing Clin Electrophysiol       Date:  1994-12       Impact factor: 1.976

10.  The salvage of infected cardiac pacemaker pockets using a closed irrigation system.

Authors:  L N Hurst; H B Evans; B Windle; G J Klein
Journal:  Pacing Clin Electrophysiol       Date:  1986-11       Impact factor: 1.976

View more
  21 in total

1.  Symptomatic occlusion of the access vein after pacemaker or ICD lead extraction.

Authors:  F A Bracke; A Meijer; L M Van Gelder
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

2.  The femoral route revisited: an alternative for pectoral pacing lead implantation.

Authors:  F A Bracke; I Ozdemir; B van Gelder
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

3.  The prevalence of methicillin resistant organisms among pacemaker and defibrillator implant recipients.

Authors:  David J Rodriguez; Aisha Afzal; Rudolph Evonich; David E Haines
Journal:  Am J Cardiovasc Dis       Date:  2012-05-15

4.  The Promise of Leadless Pacing: Based on Presentations at Nanostim Sponsored Symposium Held at the European Society of Cardiology Congress 2013, Amsterdam, The Netherlands, 2 September 2013.

Authors:  Katrina Mountfort; Reinoud Knops; Johannes Sperzel; Petr Neuzil
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

5.  Repositioning of a dislodged and fibrosed ventricular lead.

Authors:  Ejaz M Khan; Apostolos A Voudouris; R E Hood; Stephen R Shorofsky
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

6.  Complications and lead extraction in cardiac pacing and defibrillation.

Authors:  F Bracke
Journal:  Neth Heart J       Date:  2008-10       Impact factor: 2.380

Review 7.  Surgical management of cardiac implantable electronic device infections.

Authors:  Michael Koutentakis; Stavros Siminelakis; Panagiotis Korantzopoulos; Anastasios Petrou; Alexandra Petrou; Helen Priavali; Eleftheria Priavali; Andreas Mpakas; Helen Gesouli; Eleftheria Gesouli; Efstratios Apostolakis; Eleftheria Apostolakis; Kosmas Tsakiridis; Paul Zarogoulidis; Nikolaos Katsikogiannis; Ioanna Kougioumtzi; Nikolaos Machairiotis; Theodora Tsiouda; Konstantinos Zarogoulidis
Journal:  J Thorac Dis       Date:  2014-03       Impact factor: 2.895

Review 8.  Candida infections of medical devices.

Authors:  Erna M Kojic; Rabih O Darouiche
Journal:  Clin Microbiol Rev       Date:  2004-04       Impact factor: 26.132

9.  New perspectives of infections in cardiovascular disease.

Authors:  Ignatius W Fong
Journal:  Curr Cardiol Rev       Date:  2009-05

10.  A case of pacing lead induced clinical superior vena cava syndrome: a case report.

Authors:  Mukesh Singh; Sabry K Talab
Journal:  Cases J       Date:  2009-06-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.