Literature DB >> 10490481

Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system.

V P Vassilikos1, T N Maounis, J Chiladakis, D V Cokkinos, A S Manolis.   

Abstract

In the implantable cardioverter defibrillator era the necessity for lead removal is not negligible. A specially designed extraction lead system for percutaneous removal of such leads is lacking, in contrast to the existing pacing lead extraction systems. We report the successful percutaneous extraction of four implantable cardioverter defibrillator leads in three patients because of lead malfunction using a novel pacemaker lead extraction system, the VascoExtor (VascoMed) system. Three leads were successfully removed in two patients using traction with special locking stylets from the superior approach. One lead was removed using the system's additional extraction tools through the femoral approach. There were no complications. This preliminary experience shows that the VascoExtor (VascoMed) pacemaker lead extraction system can also be used in implantable cardioverter defibrillator lead extraction safely and effectively. In addition to the locking stylets, adjunct percutaneous extraction tools may be needed in some cases.

Entities:  

Mesh:

Year:  1999        PMID: 10490481     DOI: 10.1023/a:1009899708781

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  7 in total

1.  The Dotter retriever and pigtail catheter: efficacy in extraction of chronic transvenous pacemaker leads.

Authors:  R E Espinosa; D L Hayes; R E Vlietstra; M J Osborn; M D McGoon
Journal:  Pacing Clin Electrophysiol       Date:  1993-12       Impact factor: 1.976

2.  Three-year experience with a stylet for lead extraction: a multicenter study.

Authors:  E Alt; J Neuzner; L Binner; K Göhl; J C Res; U H Knabe; M Zehender; J Reinhardt
Journal:  Pacing Clin Electrophysiol       Date:  1996-01       Impact factor: 1.976

3.  Removal of endocardial defibrillation leads.

Authors:  L Jordaens; Y Van Belleghem; L Herregods
Journal:  Pacing Clin Electrophysiol       Date:  1996-01       Impact factor: 1.976

4.  Successful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.

Authors:  A S Manolis; T N Maounis; J Chiladakis; V Vassilikos; H Melita-Manolis; D V Cokkinos
Journal:  Am J Cardiol       Date:  1998-04-01       Impact factor: 2.778

5.  Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database.

Authors:  H J Smith; N E Fearnot; C L Byrd; B L Wilkoff; C J Love; T D Sellers
Journal:  Pacing Clin Electrophysiol       Date:  1994-11       Impact factor: 1.976

6.  Management of infected implantable cardiac defibrillators.

Authors:  L E Samuels; F L Samuels; M S Kaufman; R J Morris; S K Brockman
Journal:  Ann Thorac Surg       Date:  1997-12       Impact factor: 4.330

7.  Infections in implantable cardioverter defibrillator patients.

Authors:  D Wunderly; J Maloney; T Edel; M McHenry; P M McCarthy
Journal:  Pacing Clin Electrophysiol       Date:  1990-11       Impact factor: 1.976

  7 in total
  3 in total

Review 1.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

2.  Endovascular extraction techniques: Part 3: Results and indications in patients with an ICD.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-06       Impact factor: 2.380

3.  Transvenous lead extraction: Can it be simple yet safe?

Authors:  Antonios P Antoniadis; Vassilios P Vassilikos
Journal:  Anatol J Cardiol       Date:  2017-10       Impact factor: 1.596

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.