Literature DB >> 11141204

Cardiac lead extraction with a novel locking stylet.

C Kennergren1, R H Schaerf, T D Sellers, B L Wilkoff, C L Byrd, G F Tyres, S Coe, C W Coates, C Reiser.   

Abstract

Extraction of chronically implanted pacing and defibrillator leads is facilitated by using specialized locking stylets placed in the lead to allow application of traction and to stabilize the lead during sheath dissection of fibrotic tissue. We report the initial multicenter series of cases using a novel lead locking device (LLD). In 57 consecutive patients presenting at 6 institutions for lead extraction, 99 leads were treated using the LLD. After removing the pulse generator, leads were severed, the inner coil dilated and an LLD was successfully inserted and locked in the inner lumen of 95/99 (96 %) leads. With traction applied to the LLD, a variety of sheaths were advanced over the lead body to separate it from adhesions. In 97/99 (98 %) leads, all or most of the lead was removed via the implant vein; 2 leads were removed via the femoral vein. No major complications were observed. The LLD deploys safely and reliably, and provides stable support for advancement of dissecting sheaths.

Entities:  

Mesh:

Year:  2000        PMID: 11141204     DOI: 10.1023/a:1026561414148

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  9 in total

1.  Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.

Authors:  B L Wilkoff; C L Byrd; C J Love; D L Hayes; T D Sellers; R Schaerf; V Parsonnet; L M Epstein; R A Sorrentino; C Reiser
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

Review 2.  Lead extraction. Indications and techniques.

Authors:  C L Byrd; S J Schwartz; N Hedin
Journal:  Cardiol Clin       Date:  1992-11       Impact factor: 2.213

3.  Intravascular lead extraction using locking stylets and sheaths.

Authors:  C L Byrd; S J Schwartz; N B Hedin; L B Goode; N E Fearnot; H J Smith
Journal:  Pacing Clin Electrophysiol       Date:  1990-12       Impact factor: 1.976

4.  Three-year experience with a stylet for lead extraction: a multicenter study.

Authors:  E Alt; J Neuzner; L Binner; K Göhl; J C Res; U H Knabe; M Zehender; J Reinhardt
Journal:  Pacing Clin Electrophysiol       Date:  1996-01       Impact factor: 1.976

5.  Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database.

Authors:  H J Smith; N E Fearnot; C L Byrd; B L Wilkoff; C J Love; T D Sellers
Journal:  Pacing Clin Electrophysiol       Date:  1994-11       Impact factor: 1.976

6.  Excimer laser assisted extraction of permanent pacemaker and ICD leads: present experiences of a European multi-centre study.

Authors:  C Kennergren
Journal:  Eur J Cardiothorac Surg       Date:  1999-06       Impact factor: 4.191

7.  Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.

Authors:  L M Epstein; C L Byrd; B L Wilkoff; C J Love; T D Sellers; D L Hayes; C Reiser
Journal:  Circulation       Date:  1999-08-03       Impact factor: 29.690

8.  Intravascular lead extraction using locking stylets, sheaths, and other techniques.

Authors:  N E Fearnot; H J Smith; L B Goode; C L Byrd; B L Wilkoff; T D Sellers
Journal:  Pacing Clin Electrophysiol       Date:  1990-12       Impact factor: 1.976

9.  Length of hospital stay and complications after percutaneous transluminal coronary angioplasty. Clinical and procedural predictors. Heparin Registry Investigators.

Authors:  M W Wolfe; G S Roubin; M Schweiger; J M Isner; J J Ferguson; A D Cannon; M Cleman; H Cabin; F Leya; R Bonan
Journal:  Circulation       Date:  1995-08-01       Impact factor: 29.690

  9 in total
  6 in total

Review 1.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

2.  Durability of repaired pacemaker leads in the pediatric population.

Authors:  Sarah Chambers; Alex Rusanov; Henry M Spotnitz; Eric S Silver; Leonardo Liberman
Journal:  J Interv Card Electrophysiol       Date:  2011-02-16       Impact factor: 1.900

3.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

Review 4.  Pacemaker and ICD leads: strategies for long-term management.

Authors:  P Peter Borek; Bruce L Wilkoff
Journal:  J Interv Card Electrophysiol       Date:  2008-04-08       Impact factor: 1.900

5.  Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

Authors:  Antonis S Manolis; Georgios Georgiopoulos; Sofia Metaxa; Spyridon Koulouris; Dimitris Tsiachris
Journal:  Anatol J Cardiol       Date:  2017-08-11       Impact factor: 1.596

6.  Risk Factors Predicting Complications of Transvenous Lead Extraction.

Authors:  Wojciech Jacheć; Anna Polewczyk; Maciej Polewczyk; Andrzej Tomasik; Marianna Janion; Andrzej Kutarski
Journal:  Biomed Res Int       Date:  2018-12-18       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.