Abstract

The isthmic diameter of the vertebral pedicle is an important dimension affecting the stability of transpedicular screwing. The isthmic diameter of the pedicle was measured in the lumbar spines of 18 Japanese cadavers (10 male, 8 female) by axial computed tomographic (CT) scan and directly with calipers. In L1 and L2, there was no significant difference between the average value of the isthmic diameter as determined by the two methods (Student's t-test). However, in L3-5, the average value of the isthmic diameter as determined by axial CT scan was significantly greater than that given by caliper measurement. In view of the fact that caudally the longitudinal axis of the pedicle diverges towards the mid-line of the vertebral body in the coronal plane, the plane of the CT scan cannot be parallel to the real isthmic diameter of the pedicle. Therefore, it is suggested that below L2 the diameter as determined by axial CT scanning is greater than the real isthmic diameter.

Entities:  

Mesh:

Year:  1994        PMID: 7824985     DOI: 10.1007/bf00223089

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  8 in total

1.  Posterior lumbar interbody fusion and plates.

Authors:  A D Steffee; D J Sitkowski
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

2.  Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size.

Authors:  G R Misenhimer; R D Peek; L L Wiltse; S L Rothman; E H Widell
Journal:  Spine (Phila Pa 1976)       Date:  1989-04       Impact factor: 3.468

3.  Complications with the variable spinal plating system.

Authors:  T S Whitecloud; J C Butler; J L Cohen; P D Candelora
Journal:  Spine (Phila Pa 1976)       Date:  1989-04       Impact factor: 3.468

4.  Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation.

Authors:  M H Krag; D L Weaver; B D Beynnon; L D Haugh
Journal:  Spine (Phila Pa 1976)       Date:  1988-01       Impact factor: 3.468

5.  A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine.

Authors:  M R Zindrick; L L Wiltse; E H Widell; J C Thomas; W R Holland; B T Field; C W Spencer
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

6.  Morphometry of the lumbar spine: anatomical perspectives related to transpedicular fixation.

Authors:  J M Olsewski; E H Simmons; F C Kallen; F C Mendel; C M Severin; D L Berens
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

7.  Pedicle diameter determined by computed tomography. Its relevance to pedicle screw fixation in the lumbar spine.

Authors:  T N Bernard; C E Seibert
Journal:  Spine (Phila Pa 1976)       Date:  1992-06       Impact factor: 3.468

8.  An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine.

Authors:  S Soshi; R Shiba; H Kondo; K Murota
Journal:  Spine (Phila Pa 1976)       Date:  1991-11       Impact factor: 3.468

  8 in total
  6 in total

Review 1.  Ethnic differences in pedicle and bony spinal canal dimensions calculated from computed tomography of the cervical spine: a review of the English-language literature.

Authors:  Masaaki Chazono; Takaaki Tanaka; Yoshio Kumagae; Tomoaki Sai; Keishi Marumo
Journal:  Eur Spine J       Date:  2012-04-19       Impact factor: 3.134

2.  Comparative assessment of pedicle morphology of the lumbar spine in various degenerative diseases.

Authors:  Kenya Nojiri; Morio Matsumoto; Kazuhiro Chiba; Yoshiaki Toyama; Suketaka Momoshima
Journal:  Surg Radiol Anat       Date:  2005-11-09       Impact factor: 1.246

3.  Pedicular: of lice and men.

Authors:  F M Hall
Journal:  Skeletal Radiol       Date:  1995-05       Impact factor: 2.199

4.  Morphometric analysis of the thoracic and lumbar spine in Japanese on the use of pedicle screws.

Authors:  Kenya Nojiri; Morio Matsumoto; Kazuhiro Chiba; Yoshiaki Toyama
Journal:  Surg Radiol Anat       Date:  2005-01-12       Impact factor: 1.246

5.  Computerized Tomography-Based Morphometric Analysis of Subaxial Cervical Spine Pedicle in Asymptomatic Indian Population.

Authors:  Kamran Farooque; Rahul Yadav; Buddhadev Chowdhury; Shivanand Gamanagatti; Atin Kumar; Pradeep Kumar Meena
Journal:  Int J Spine Surg       Date:  2018-08-03

6.  Radiographic anatomical relationship between spinous process and pedicle in thoracolumbar and lumbar spine.

Authors:  Xingang Cui; Guodong Wang
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.