Literature DB >> 3381134

Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation.

M H Krag1, D L Weaver, B D Beynnon, L D Haugh.   

Abstract

Vertebral transpedicular screws provide secure attachment for posterior spinal fixation devices. Screw design details, biomechanics, and implantation safety depend upon anatomic constraints, especially from the pedicle and body. Previous morphometric data were limited; thus, a retrospective study was undertaken using computerized axial tomograms (CT) of 91 vertebrae (T9-L5). In addition, eight cadaver vertebrae were CT scanned and then cut transversely to compare x-ray measurements with direct physical measurements. Measured parameters included pedicle width, pedicle length, angle of pedicle axis to sagittal plane, and transpedicular cortex-to-cortex chord length. Good correlation is shown to occur between CT scan and direct physical measurements of human vertebrae. Implications for spinal implant screw dimensions and safety of implantation are discussed. Comparison with previously available data is made.

Entities:  

Mesh:

Year:  1988        PMID: 3381134     DOI: 10.1097/00007632-198801000-00007

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  49 in total

1.  Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests.

Authors:  Laurent Balabaud; Emeric Gallard; Wafa Skalli; Bernard Dupas; Robert Roger; François Lavaste; Jean-Paul Steib
Journal:  Eur Spine J       Date:  2003-04-05       Impact factor: 3.134

2.  Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

Authors:  Takahiro Makino; Takashi Kaito; Hiroyasu Fujiwara; Kazuo Yonenobu
Journal:  Eur Spine J       Date:  2012-02-19       Impact factor: 3.134

3.  Current issues with standards in the measurement and documentation of human skeletal anatomy.

Authors:  Justin Magee; Brian McClelland; John Winder
Journal:  J Anat       Date:  2012-07-02       Impact factor: 2.610

4.  Comparison of radiographic and computed tomographic measurement of pedicle and vertebral body dimensions in Koreans: the ratio of pedicle transverse diameter to vertebral body transverse diameter.

Authors:  Ki Ser Kang; Kwang-Sup Song; Jong Seok Lee; Jae Jun Yang; In Sup Song
Journal:  Eur Spine J       Date:  2010-08-30       Impact factor: 3.134

5.  Assessment of the morpho-densitometric parameters of the lumbar pedicles in osteoporotic and control women undergoing routine abdominal MDCT examinations.

Authors:  Antonios E Papadakis; Apostolos H Karantanas; Giorgos Papadokostakis; John Damilakis
Journal:  J Bone Miner Metab       Date:  2010-10-26       Impact factor: 2.626

6.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

7.  Comparison of pullout strength of the thoracic pedicle screw between intrapedicular and extrapedicular technique: a meta-analysis and literature review.

Authors:  Hua Wang; Huafeng Wang; Shilabant Sen Sribastav; Fubiao Ye; Chunxiang Liang; Zemin Li; Jianru Wang; Hui Liu; Xin Wang; Zhaomin Zheng
Journal:  Int J Clin Exp Med       Date:  2015-12-15

8.  Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine.

Authors:  Shiu-Bii Lien; Nien-Hsien Liou; Shing-Sheng Wu
Journal:  Eur Spine J       Date:  2006-12-19       Impact factor: 3.134

9.  Application of multislice spiral CT for guidance of insertion of thoracic spine pedicle screws: an in vitro study.

Authors:  Juan Wang; Yicheng Zhou; Ning Hu; Renfa Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006

10.  Ideal entry point for the thoracic pedicle screw during the free hand technique.

Authors:  Kook Jin Chung; Seung Woo Suh; Sameer Desai; Hae Ryong Song
Journal:  Int Orthop       Date:  2007-04-17       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.