| Literature DB >> 23450217 |
Jins John1, V Rangarajan, Ravindra C Savadi, K S Satheesh Kumar, Preeti Satheesh Kumar.
Abstract
Today implant dentistry has made great inroads into the treatment modalities that are available in treating an edentulous patient. Popularity of a two implant retained overdenture has created a necessity to examine the various attachment systems being used and the stresses that are transmitted to the alveolar bone. Hence a Three dimensional Finite Element Analysis was done to analyze the stress distribution in the mandibular bone with implant-supported overdenture having Ball/O-ring and Magnet attachments of different diameters. A segment of the anterior region of the mandible was modeled with implant and the overdenture. Four different models were generated having Ball/O-Ring and Magnet Attachments. Forces of 10 N, 35 N and 70 N were applied from the horizontal, vertical and oblique directions respectively and the stress distribution studied. It was concluded that the greatest stress concentrations were seen at the crest of the cortical bone and could be reduced by using smaller sized attachments for implant supported-overdenture.Entities:
Keywords: Finite element analysis; Implant; Mandibular; Overdenture
Year: 2012 PMID: 23450217 PMCID: PMC3332316 DOI: 10.1007/s13191-012-0114-0
Source DB: PubMed Journal: J Indian Prosthodont Soc ISSN: 0972-4052