Literature DB >> 7766973

A complex-difference phase-contrast technique for measurement of volume flow rates.

J A Polzin1, M T Alley, F R Korosec, T M Grist, Y Wang, C A Mistretta.   

Abstract

Magnetic resonance (MR) phase-difference methods work well for measuring volumetric flow rates when the vessel diameter is large compared with the in-plane voxel dimensions. For small vessels (eg, coronary arteries), partial-volume effects introduce substantial errors in the measured volume flow rate. To correctly measure flow rates through a voxel, both the fraction of the voxel containing moving spins and the phase shift imparted to those spins must be known. The authors propose a flow measurement method that combines information obtained with both the complex-difference and phase-difference processing techniques and thereby provides the fractional volume occupied by the moving spins and the phase of those spins. The complex-difference flow map method proposed results in improved accuracy of MR phase-contrast flow measurements in the presence of partial-volume effects.

Mesh:

Year:  1995        PMID: 7766973     DOI: 10.1002/jmri.1880050202

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  Real-time volumetric flow measurements with complex-difference MRI.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

2.  Flow-gated phase-contrast MRI using radial acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

3.  Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta.

Authors:  Umberto Morbiducci; Raffaele Ponzini; Giovanna Rizzo; Marco Evanghelos Biancolini; Francesco Iannaccone; Diego Gallo; Alberto Redaelli
Journal:  Med Biol Eng Comput       Date:  2011-12-23       Impact factor: 2.602

4.  Partial field-of-view spiral phase-contrast imaging using complex difference processing.

Authors:  Reza Nezafat; Richard B Thompson; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

5.  Flow-gated radial phase-contrast imaging in the presence of weak flow.

Authors:  Hsu-Hsia Peng; Teng-Yi Huang; Fu-Nien Wang; Hsiao-Wen Chung
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-03       Impact factor: 2.357

6.  Time-resolved absolute velocity quantification with projections.

Authors:  Michael C Langham; Varsha Jain; Jeremy F Magland; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2010-07-30       Impact factor: 4.668

7.  Chemical shift-induced phase errors in phase-contrast MRI.

Authors:  Matthew J Middione; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2012-04-06       Impact factor: 4.668

8.  Modeling Bias Error in 4D Flow MRI Velocity Measurements.

Authors:  Sean M Rothenberger; Jiacheng Zhang; Melissa C Brindise; Susanne Schnell; Michael Markl; Pavlos P Vlachos; Vitaliy L Rayz
Journal:  IEEE Trans Med Imaging       Date:  2022-06-30       Impact factor: 11.037

9.  Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

Authors:  Lisa C Krishnamurthy; Peiying Liu; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

Review 10.  Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis.

Authors:  Vitaliy L Rayz; Aaron A Cohen-Gadol
Journal:  Annu Rev Biomed Eng       Date:  2020-03-25       Impact factor: 11.324

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.