Literature DB >> 23568830

Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

Lisa C Krishnamurthy1, Peiying Liu, Yulin Ge, Hanzhang Lu.   

Abstract

PURPOSE: Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY: The method, T2-Relaxation-Under-Phase-Contrast MRI, utilizes complex subtraction of phase-contrast to isolate pure blood signal, applies nonslice-selective T2-preparation to measure T2, and converts T2 to oxygenation using a calibration plot.
METHODS: Following feasibility demonstration, several technical aspects were examined, including validation with an established global Yv technique, test-retest reproducibility, sensitivity to detect oxygenation changes due to hypoxia and caffeine challenges, applicability of echo-planar-imaging (EPI) acquisition to shorten scan duration, and ability to study veins with a caliber of 1-2 mm.
RESULTS: T2-Relaxation-Under-Phase-Contrast was able to simultaneously measure Yv in all major veins in the brain, including sagittal sinus, straight sinus, great vein, and internal cerebral vein. T2-Relaxation-Under-Phase-Contrast results showed an excellent agreement with the reference technique, high sensitivity to oxygenation changes, and test-retest variability of 3.5 ± 1.0%. The use of segmented-EPI was able to reduce the scan duration to 1.5 minutes. It was also feasible to study pial veins and deep veins.
CONCLUSION: T2-Relaxation-Under-Phase-Contrast MRI is a promising technique for vessel-specific oxygenation measurement.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 23568830      PMCID: PMC3972354          DOI: 10.1002/mrm.24750

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  66 in total

1.  Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies.

Authors:  G S Pell; D L Thomas; M F Lythgoe; F Calamante; A M Howseman; D G Gadian; R J Ordidge
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

2.  Rapid quantitative measurement of CMRO(2) and CBF by dual administration of (15)O-labeled oxygen and water during a single PET scan-a validation study and error analysis in anesthetized monkeys.

Authors:  Nobuyuki Kudomi; Takuya Hayashi; Noboru Teramoto; Hiroshi Watabe; Naoki Kawachi; Youichirou Ohta; Kyeong Min Kim; Hidehiro Iida
Journal:  J Cereb Blood Flow Metab       Date:  2005-09       Impact factor: 6.200

3.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

4.  Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state.

Authors:  Xiang He; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

5.  Comparison of phase-difference and complex-difference processing in phase-contrast MR angiography.

Authors:  M A Bernstein; Y Ikezaki
Journal:  J Magn Reson Imaging       Date:  1991 Nov-Dec       Impact factor: 4.813

6.  Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET.

Authors:  Masanobu Ibaraki; Shuichi Miura; Eku Shimosegawa; Shigeki Sugawara; Tetsuro Mizuta; Akihiro Ishikawa; Masaharu Amano
Journal:  J Nucl Med       Date:  2007-12-12       Impact factor: 10.057

Review 7.  Energy failure in multiple sclerosis and its investigation using MR techniques.

Authors:  David Paling; Xavier Golay; Claudia Wheeler-Kingshott; Raju Kapoor; David Miller
Journal:  J Neurol       Date:  2011-06-10       Impact factor: 4.849

8.  Baseline blood oxygenation modulates response amplitude: Physiologic basis for intersubject variations in functional MRI signals.

Authors:  Hanzhang Lu; Chenguang Zhao; Yulin Ge; Kelly Lewis-Amezcua
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 9.  PET: blood flow and oxygen consumption in brain tumors.

Authors:  K L Leenders
Journal:  J Neurooncol       Date:  1994       Impact factor: 4.130

10.  Local cerebral blood volume in head-injured patients. Determination by emission computed tomography of 99mTc-labeled red cells.

Authors:  D E Kuhl; A Alavi; E J Hoffman; M E Phelps; R A Zimmerman; W D Obrist; D A Bruce; J H Greenberg; B Uzzell
Journal:  J Neurosurg       Date:  1980-03       Impact factor: 5.115

View more
  32 in total

1.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

2.  Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.

Authors:  Peiying Liu; Ivan Dimitrov; Trevor Andrews; David E Crane; Jacinda K Dariotis; John Desmond; Julie Dumas; Guillaume Gilbert; Anand Kumar; Bradley J Maclntosh; Alan Tucholka; Shaolin Yang; Guanghua Xiao; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

3.  Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Authors:  Wenbo Li; Xiang Xu; Peiying Liu; John J Strouse; James F Casella; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

4.  Quantitative assessment of cerebral venous blood T2 in mouse at 11.7T: Implementation, optimization, and age effect.

Authors:  Zhiliang Wei; Jiadi Xu; Peiying Liu; Lin Chen; Wenbo Li; Peter van Zijl; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

Review 5.  MRI-based methods for quantification of the cerebral metabolic rate of oxygen.

Authors:  Zachary B Rodgers; John A Detre; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2016-04-18       Impact factor: 6.200

6.  Cross-vendor harmonization of T2 -relaxation-under-spin-tagging (TRUST) MRI for the assessment of cerebral venous oxygenation.

Authors:  Dengrong Jiang; Peiying Liu; Yang Li; Deng Mao; Cuimei Xu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-01-25       Impact factor: 4.668

7.  Non-contrast MR imaging of blood-brain barrier permeability to water.

Authors:  Zixuan Lin; Yang Li; Pan Su; Deng Mao; Zhiliang Wei; Jay J Pillai; Abhay Moghekar; Matthias van Osch; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-03-01       Impact factor: 4.668

8.  Reduced deep regional cerebral venous oxygen saturation in hemodialysis patients using quantitative susceptibility mapping.

Authors:  Chao Chai; Saifeng Liu; Linlin Fan; Lei Liu; Jinping Li; Chao Zuo; Tianyi Qian; E Mark Haacke; Wen Shen; Shuang Xia
Journal:  Metab Brain Dis       Date:  2017-12-16       Impact factor: 3.584

9.  Normal variations in brain oxygen extraction fraction are partly attributed to differences in end-tidal CO2.

Authors:  Dengrong Jiang; Zixuan Lin; Peiying Liu; Sandeepa Sur; Cuimei Xu; Kaisha Hazel; George Pottanat; Sevil Yasar; Paul Rosenberg; Marilyn Albert; Hanzhang Lu
Journal:  J Cereb Blood Flow Metab       Date:  2019-08-05       Impact factor: 6.200

10.  Rapid T2- and susceptometry-based CMRO2 quantification with interleaved TRUST (iTRUST).

Authors:  Zachary B Rodgers; Erin K Englund; Michael C Langham; Jeremy F Magland; Felix W Wehrli
Journal:  Neuroimage       Date:  2014-11-04       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.