Literature DB >> 7671498

Polyethylene wear in total hip arthroplasty.

A B Bankston1, H Cates, M A Ritter, E M Keating, P M Faris.   

Abstract

Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined polyethylene cups. Two patient groups were matched individually for gender, age, weight, and length of followup. Analyses were done using the technique of Livermore et al. The bearing surface evaluation consisted of 3 groups after matching, leaving 77 patients per group. Results showed linear wear rates of 0.06 mm per year, 0.05 mm per year, and 0.08 mm per year for stainless steel, cobalt chrome, and titanium alloy, respectively. The comparison between cemented molded metal-backed and nonmetal-backed acetabular components was not matched, with 134 metal-backed and 99 nonmetal-backed components. Results showed linear wear rates of 0.011 mm per year in the metal-backed group and 0.08 mm per year in the nonmetal-backed group. Results were statistically significant. These results indicate that the metal composition of the femoral bearing surface has minimal, if any, effect on the linear polyethylene wear rate. The method of polyethylene fabrication and the use of metal backing had a significant effect on the polyethylene wear rate in these patient groups. These results suggest that the compression-molded all-polyethylene acetabular component may be optimal for reducing polyethylene wear in total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7671498

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

4.  Polyethylene wear is influenced by manufacturing technique in modular TKA.

Authors:  Adolph V Lombardi; Bradley S Ellison; Keith R Berend
Journal:  Clin Orthop Relat Res       Date:  2008-09-13       Impact factor: 4.176

5.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

Review 6.  Ultra-High-Molecular-Weight-Polyethylene (UHMWPE) as a Promising Polymer Material for Biomedical Applications: A Concise Review.

Authors:  Muzamil Hussain; Rizwan Ali Naqvi; Naseem Abbas; Shahzad Masood Khan; Saad Nawaz; Arif Hussain; Nida Zahra; Muhammad Waqas Khalid
Journal:  Polymers (Basel)       Date:  2020-02-04       Impact factor: 4.329

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.