Literature DB >> 18791779

Polyethylene wear is influenced by manufacturing technique in modular TKA.

Adolph V Lombardi1, Bradley S Ellison, Keith R Berend.   

Abstract

Polyethylene insert backside surface wear is implicated in osteolysis and failure of total knee arthroplasty. Manufacturing and sterilization methods reduce articular-sided wear. We questioned whether manufacturing technique influences the severity of backside wear. We examined 39 explanted tibial bearings in a blinded fashion using visual, stereomicroscopic, and scanning electron microscopic techniques. We examined 26 direct compression molded components and 13 nondirect compression molded components and applied a new backside wear severity score. The score characterized the magnitude of the various modes of wear with severity ranging from 0 (no wear) to 27 (severe wear). Time in vivo, tibial baseplate material, and manufacturing technique were used as variables for comparison. Backside wear was related to polyethylene manufacturing process with direct compression molded implants having a wear score of 2.3 and nondirect compression molded a score of 5.7. Time in vivo influenced backside wear, although direct compression molded predicted decreased backside wear independent of time in vivo. The data suggest manufacturing technique influences backside wear in total knee arthroplasty polyethylene inserts.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18791779      PMCID: PMC2565045          DOI: 10.1007/s11999-008-0470-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  38 in total

1.  Measures for reducing ultra-high-molecular-weight polyethylene wear in total knee replacement: a simulator study.

Authors:  Ralf Mueller-Rath; Bernhard Kleffner; Stefan Andereya; Torsten Mumme; Dieter Christian Wirtz
Journal:  Biomed Tech (Berl)       Date:  2007-08       Impact factor: 1.411

2.  The Coventry Award. Modular tibial insert micromotion. A concern with contemporary knee implants.

Authors:  N L Parks; G A Engh; L D Topoleski; J Emperado
Journal:  Clin Orthop Relat Res       Date:  1998-11       Impact factor: 4.176

Review 3.  Wear in total hip and knee replacements.

Authors:  T P Schmalzried; J J Callaghan
Journal:  J Bone Joint Surg Am       Date:  1999-01       Impact factor: 5.284

4.  The correlation of RANK, RANKL and TNFalpha expression with bone loss volume and polyethylene wear debris around hip implants.

Authors:  Christopher A Holding; David M Findlay; Roumen Stamenkov; Susan D Neale; Helen Lucas; A S S K Dharmapatni; Stuart A Callary; Kush R Shrestha; Gerald J Atkins; Donald W Howie; David R Haynes
Journal:  Biomaterials       Date:  2006-06-27       Impact factor: 12.479

5.  Prodromes of failure in total knee arthroplasty.

Authors:  J H Lonner; J M Siliski; R D Scott
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

6.  Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss.

Authors:  Michael A Conditt; Matthew T Thompson; Molly M Usrey; Sabir K Ismaily; Philip C Noble
Journal:  J Bone Joint Surg Am       Date:  2005-02       Impact factor: 5.284

7.  Overview of polyethylene as a bearing material: comparison of sterilization methods.

Authors:  J P Collier; L C Sutula; B H Currier; J H Currier; R E Wooding; I R Williams; K B Farber; M B Mayor
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

8.  Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements.

Authors:  T P Schmalzried; P Campbell; A K Schmitt; I C Brown; H C Amstutz
Journal:  J Biomed Mater Res       Date:  1997

9.  Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements.

Authors:  Thomas K Fehring; Jeffrey A Murphy; T David Hayes; Donald W Roberts; Donald L Pomeroy; William L Griffin
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

10.  Backside wear of Miller-Galante I and Insall-Burstein II tibial inserts.

Authors:  Naoya Taki; Victor M Goldberg; Matthew J Kraay; Clare M Rimnac
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

View more
  8 in total

1.  The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts.

Authors:  Nicholas R Paterson; Matthew G Teeter; Steven J MacDonald; Richard W McCalden; Douglas D R Naudie
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

2.  Changes in surface topography at the TKA backside articulation following in vivo service: a retrieval analysis.

Authors:  Richard J Holleyman; Susan C Scholes; David Weir; Simon S Jameson; Jim Holland; Tom J Joyce; David J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

3.  Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.

Authors:  Matthew P Abdel; Mark W Gesell; Christen W Hoedt; Kathleen N Meyers; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-04-15       Impact factor: 4.176

4.  Comparison of patellofemoral outcomes after TKA using two prostheses with different patellofemoral design features.

Authors:  Dae Kyung Bae; Jong Hun Baek; Kyung Tack Yoon; Hyuck Sung Son; Sang Jun Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-10       Impact factor: 4.342

5.  Better survival of total knee replacement in patients older than 70 years: a prospective study with 8 to 12 years follow-up.

Authors:  Ricardo Fernandez-Fernandez; E Carlos Rodriguez-Merchan
Journal:  Arch Bone Jt Surg       Date:  2015-01-15

6.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

7.  Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty.

Authors:  Łukasz Łapaj; Adrian Mróz; Paweł Kokoszka; Jacek Markuszewski; Justyna Wendland; Celina Helak-Łapaj; Jacek Kruczyński
Journal:  Acta Orthop       Date:  2016-10-26       Impact factor: 3.717

8.  Comparison of conventional polyethylene wear and signs of cup failure in two similar total hip designs.

Authors:  Thomas B Pace; Kevin C Keith; Estefania Alvarez; Rebecca G Snider; Stephanie L Tanner; John D Desjardins
Journal:  Adv Orthop       Date:  2013-04-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.