Radiographic measurement of wear in 5 cohorts of patients observed for 5 to 22 years.

J J Callaghan1, D R Pedersen, J P Olejniczak, D D Goetz, R C Johnston.   

Abstract

Standardized wear measurements using a tablet digitizer were made on long-term serial radiographs for 5 cohorts of total hip replacements to determine any differences in acetabular component polyethylene wear rates. The 5 groups included 4 cemented acetabular component series and 1 cementless acetabular component series. Comparing the rates of linear wear for the 5 groups, 22-mm-head components had similar wear when compared with the 28-mm-head components, both cemented and uncemented, and volumetric wear rates were greater for the cemented 28-mm-head components than for the 22-mm-head components. Although molded 22-mm-head components had less wear than the machined 22-mm-head components, there was no statistically significant difference between the 2. The uncemented metal-backed component with 28-mm-head articulation showed no accelerated wear when compared with the cemented metal-backed components at a shorter 5-year followup. The constant variable in all series was a cemented femoral component.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7671468

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

Review 2.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

3.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

Review 4.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

5.  What Can We Learn From 20-year Followup Studies of Hip Replacement?

Authors:  Christopher T Martin; John J Callaghan; Yubo Gao; Andrew J Pugely; Steve S Liu; Lucian C Warth; Devon D Goetz
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

6.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003

7.  Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data.

Authors:  R Kosak; V Antolic; V Pavlovcic; V Kralj-Iglic; I Milosev; G Vidmar; A Iglic
Journal:  Skeletal Radiol       Date:  2003-09-13       Impact factor: 2.199

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.