Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems.

W C Hellinger1, J J Cawley, S Alvarez, S F Hogan, W S Harmsen, D M Ilstrup, F R Cockerill.   

Abstract

The performance characteristics of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) aerobic blood culture systems were compared for 6,009 blood culture sets obtained from patients with suspected bloodstream infections. The BacT/Alert aerobic bottle [BTA(O2)] was continuously agitated while it was incubated in 5% CO2 at 36 degrees C; culture plates prepared from the Isolator tube [I(O2)] were incubated in 5% CO2 at 37 degrees C. From 394 blood cultures, 416 clinically significant isolates of bacteria and yeasts were recovered. The overall yields for BTA(O2) and I(O2) were not significantly different (319 versus 336; P = 0.20). I(O2) recovered significantly more staphylococcus (P < 0.05) and yeast isolates (P < 0.01). BTA(O2) recovered significantly more aerobic and facultatively anaerobic gram-negative bacilli (P < 0.05). In blood culture sets which produced growth of the same organisms in both the BTA(O2) and I(O2) systems, the BTA(O2) system detected growth sooner, but more rapid identification was possible with the I(O2) system by virtue of earlier isolation of colonies on solid media.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7665647      PMCID: PMC228270          DOI: 10.1128/jcm.33.7.1787-1790.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.

Authors:  N K Henry; C M Grewell; P E Van Grevenhof; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

2.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

3.  Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems.

Authors:  P Zwadyk; C L Pierson; C Young
Journal:  J Clin Microbiol       Date:  1994-05       Impact factor: 5.948

4.  Clinical comparison of isolator and thiol broth with ESP aerobic and anaerobic bottles for recovery of pathogens from blood.

Authors:  J A Kellogg; D A Bankert; J P Manzella; K S Parsey; S L Scott; S H Cavanaugh
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

5.  Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1993-08       Impact factor: 5.948

6.  Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; J A Washington
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

  6 in total
  13 in total

1.  Performance of five agar media for recovery of fungi from isolator blood cultures.

Authors:  G W Procop; F R Cockerill; E A Vetter; W S Harmsen; J G Hughes; G D Roberts
Journal:  J Clin Microbiol       Date:  2000-10       Impact factor: 5.948

Review 2.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

3.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

4.  Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems.

Authors:  B L Wasilauskas; R Morrell
Journal:  J Clin Microbiol       Date:  1996-03       Impact factor: 5.948

5.  Rapid Detection and Identification of Candidemia by Direct Blood Culturing on Solid Medium by Use of Lysis-Centrifugation Method Combined with Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS).

Authors:  Evgeny A Idelevich; Barbara Grünastel; Karsten Becker
Journal:  J Clin Microbiol       Date:  2016-12-28       Impact factor: 5.948

Review 6.  Microbiological and clinical aspects of infection associated with Stenotrophomonas maltophilia.

Authors:  M Denton; K G Kerr
Journal:  Clin Microbiol Rev       Date:  1998-01       Impact factor: 26.132

7.  Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures.

Authors:  P L Welby-Sellenriek; D S Keller; R J Ferrett; G A Storch
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

8.  Predominance of Enterobacteriaceae isolates in early positive anaerobic blood culture bottles in BacT/Alert system.

Authors:  Tzong-Shi Chiueh; Shih-Yi Lee; Sheng-Hui Tang; Jang-Jih Lu; Jun-Ren Sun
Journal:  J Clin Lab Anal       Date:  2013-01-24       Impact factor: 2.352

9.  Controlled clinical comparison of BacT/ALERT standard aerobic medium with BACTEC standard aerobic medium for culturing blood.

Authors:  Stanley Mirrett; L Barth Reller; Cathy A Petti; Christopher W Woods; Bindu Vazirani; Rekha Sivadas; Melvin P Weinstein
Journal:  J Clin Microbiol       Date:  2003-06       Impact factor: 5.948

10.  Implementation of Automated Blood Culture With Quality Assurance in a Resource-Limited Setting.

Authors:  Anja von Laer; Micheline Ahou N'Guessan; Fidèle Sounan Touré; Kathrin Nowak; Karin Groeschner; Ralf Ignatius; Johannes Friesen; Sara Tomczyk; Fabian H Leendertz; Tim Eckmanns; Chantal Akoua-Koffi
Journal:  Front Med (Lausanne)       Date:  2021-05-21
View more