Literature DB >> 8370739

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections.

B A Kirkley1, K A Easley, B A Basille, J A Washington.   

Abstract

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disease Control definitions. Statistically significant differences were found between the systems for the following organisms, which were all detected more frequently in the Isolator system: Staphylococcus aureus (P = 0.0001), Alcaligenes xylosoxidans (P = 0.008), Klebsiella pneumoniae (P = 0.05), Salmonella spp. (P = 0.03), and Candida albicans (P = 0.02). The Septi-Chek Release system required a longer period of time than the Isolator system for detection of the following organisms:S. aureus (P = 0.0001), Enterococcus spp. (P = 0.0001), Enterobacter cloacae (P = 0.03), Escherichia coli (P = 0.0001), Klebsiella oxytoca (P = 0.03), K. pneumoniae (P = 0.02), Pseudomonas aeruginosa (P = 0.002), and C. albicans (P = 0.005). There were 430 episodes of bloodstream infections identified in the study; of these episodes, only those due to S. aureus were detected significantly more frequently (P = 0.0001) by the Isolator system than by the Septi-Chek Release system. However, episodes of bloodstream infections due to S. aureus, Staphylococcus epidermidis, Enterococcus spp., and E. coli were detected significantly faster by the Isolator system.

Entities:  

Mesh:

Year:  1993        PMID: 8370739      PMCID: PMC265707          DOI: 10.1128/jcm.31.8.2114-2117.1993

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Evaluation of the new improved BHI-lysis blood culture medium for the BCB Roche system.

Authors:  P Rohner; H Burkardt; H Dreismann; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1991-08       Impact factor: 3.267

2.  Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and the isolator lysis-centrifugation system.

Authors:  P R Murray; A W Spizzo; A C Niles
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

3.  CDC definitions for nosocomial infections, 1988.

Authors:  J S Garner; W R Jarvis; T G Emori; T C Horan; J M Hughes
Journal:  Am J Infect Control       Date:  1988-06       Impact factor: 2.918

  3 in total
  6 in total

1.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

2.  Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems.

Authors:  F R Cockerill; C A Torgerson; G S Reed; E A Vetter; A L Weaver; J C Dale; G D Roberts; N K Henry; D M Ilstrup; J E Rosenblatt
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

Review 3.  Microbiological and clinical aspects of infection associated with Stenotrophomonas maltophilia.

Authors:  M Denton; K G Kerr
Journal:  Clin Microbiol Rev       Date:  1998-01       Impact factor: 26.132

4.  Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems.

Authors:  W C Hellinger; J J Cawley; S Alvarez; S F Hogan; W S Harmsen; D M Ilstrup; F R Cockerill
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

5.  Evaluation and comparison of different blood culture techniques for bacteriological isolation of Salmonella typhi and Brucella abortus.

Authors:  M M Gaviria-Ruiz; N M Cardona-Castro
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

6.  Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; J A Washington
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.