Literature DB >> 8051256

Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems.

P Zwadyk1, C L Pierson, C Young.   

Abstract

The Difco ESP and Organon Teknika BacT/Alert (BTA) systems were evaluated in a clinical study of 5,421 aerobic and 5,035 anaerobic blood cultures. Of 405 clinically significant positive cultures evaluated, 272 grew in both systems, 86 grew in ESP only, and 47 grew in BTA only (P < 0.005). Of 320 organisms detected in aerobic bottles, 208 grew in both systems, 68 grew in ESP only and 45 grew in BTA only (P < 0.05), with Staphylococcus aureus the only organism showing a statistically significant difference. The ESP anaerobic bottle also detected more anaerobes (16 of 17 versus 4 of 17, P < 0.005) and more organisms overall (57 versus 34, P < 0.05). However, with the exception of patients with anaerobic bacteremia (12 of 13 for ESP and 4 of 13 for BTA, P < 0.05), there was no statistical difference in the detection of patient episodes. Average detection time of matched aerobic bottles was 18.3 h for ESP and 22.0 h for BTA (P < 0.001). For matched pairs of anaerobic bottles, the average detection time was faster in the BTA bottles (P < 0.001), because of the growth of facultative organisms. To explore the differences in anaerobic detection more fully, 20 sets of anaerobic bottles were seeded with 12 anaerobic species mixed with human blood. ESP grew more organisms (17 of 20 versus 10 of 20, P < 0.025), and the average time to detection for the 10 paired positive cultures was 21.6 h for ESP and 50.8 h for BTA (P < 0.05). Times for loading and unloading bottles were similar for both systems.

Entities:  

Mesh:

Year:  1994        PMID: 8051256      PMCID: PMC263668          DOI: 10.1128/jcm.32.5.1273-1279.1994

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

1.  Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures.

Authors:  D J Hardy; B B Hulbert; P C Migneault
Journal:  J Clin Microbiol       Date:  1992-10       Impact factor: 5.948

2.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

3.  Multicenter comparison of MicroScan and BACTEC blood culture systems.

Authors:  B Wasilauskas; R Gay; P Zwadyk; M Pfaller; F Koontz
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

4.  Recovery of clinically important microorganisms from the BacT/Alert blood culture system does not require testing for seven days.

Authors:  M L Wilson; S Mirrett; L B Reller; M P Weinstein; L G Reimer
Journal:  Diagn Microbiol Infect Dis       Date:  1993-01       Impact factor: 2.803

5.  Comparison of the BacT/Alert pediatric blood culture system, Pedi-BacT, with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube.

Authors:  K K Krisher; D R Whyburn; F E Koepnick
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

6.  Detection of bacteremia by Difco ESP blood culture system.

Authors:  J A Morello; C Leitch; S Nitz; J W Dyke; M Andruszewski; G Maier; W Landau; M A Beard
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

7.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

  7 in total
  12 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

3.  Four-day incubation period for blood culture bottles processed with the Difco ESP blood culture system.

Authors:  G V Doern; A B Brueggemann; W M Dunne; S G Jenkins; D C Halstead; J C McLaughlin
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

4.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

5.  Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.

Authors:  L D Schwabe; R B Thomson; K K Flint; F P Koontz
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

6.  Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital.

Authors:  J A Smith; E A Bryce; J H Ngui-Yen; F J Roberts
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

7.  Times to detection of bacteria and yeasts in BACTEC 9240 blood culture bottles.

Authors:  B S Reisner; G L Woods
Journal:  J Clin Microbiol       Date:  1999-06       Impact factor: 5.948

8.  Continuous quality improvement for introduction of automated blood culture instrument.

Authors:  M Alfa; S Sanche; S Roman; Y Fiola; P Lenton; G Harding
Journal:  J Clin Microbiol       Date:  1995-05       Impact factor: 5.948

9.  Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems.

Authors:  W C Hellinger; J J Cawley; S Alvarez; S F Hogan; W S Harmsen; D M Ilstrup; F R Cockerill
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

10.  Controlled clinical comparison of BacT/ALERT standard aerobic medium with BACTEC standard aerobic medium for culturing blood.

Authors:  Stanley Mirrett; L Barth Reller; Cathy A Petti; Christopher W Woods; Bindu Vazirani; Rekha Sivadas; Melvin P Weinstein
Journal:  J Clin Microbiol       Date:  2003-06       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.