Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures.

P L Welby-Sellenriek1, D S Keller, R J Ferrett, G A Storch.   

Abstract

We compared the BacT/Alert system using the aerobic FAN bottle with the ESP system using the 80A aerobic bottle for the detection of pediatric bloodstream pathogens at a children's hospital. From 6,636 blood culture sets complying with the inclusion criteria, 308 pathogens were detected, including 177 that were detected by both systems, 69 that were detected by BacT/Alert FAN only, and 62 that were detected by ESP 80A only (P = 0.6; not significant). BacT/Alert FAN detected more isolates of Staphylococcus aureus (47 versus 34; P = 0.02), while ESP 80A detected more episodes of streptococcal and enterococcal infection. BacT/Alert FAN detected more pathogens from patients receiving antibiotic therapy (107 versus 93; P = 0.04). Of 248 separate episodes of bacteremia or fungemia, 146 were detected by both systems, 56 were detected by ESP 80A only, and 46 were detected by BacT/Alert FAN only (P = 0.37; not significant). The median times to detection were 13.6 h for ESP 80A and 15.7 h for BacT/Alert FAN (P < 0.001). Both systems were considered easy to operate and were free from significant mechanical difficulties. False-positive or false-negative signals were rare or nonexistent with both systems. We conclude that both systems rapidly detect a broad range of pediatric bloodstream pathogens. BacT/Alert FAN provides better detection of Staphylococcus aureus, especially from patients receiving antibiotics. ESP 80A provides better detection of streptococci and enterococci.

Entities:  

Mesh:

Year:  1997        PMID: 9114401      PMCID: PMC232723          DOI: 10.1128/jcm.35.5.1166-1171.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  21 in total

1.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

2.  Pediatric blood culture: comparison of yields using aerobic, anaerobic and hypertonic media.

Authors:  M E Weisse; J W Bass; L M Young
Journal:  Pediatr Infect Dis J       Date:  1992-02       Impact factor: 2.129

3.  Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).

Authors:  F S Nolte; J M Williams; R C Jerris; J A Morello; C D Leitch; S Matushek; L D Schwabe; F Dorigan; F E Kocka
Journal:  J Clin Microbiol       Date:  1993-03       Impact factor: 5.948

4.  Comparison of the BacT/Alert pediatric blood culture system, Pedi-BacT, with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube.

Authors:  K K Krisher; D R Whyburn; F E Koepnick
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

5.  Detection of bacteremia by Difco ESP blood culture system.

Authors:  J A Morello; C Leitch; S Nitz; J W Dyke; M Andruszewski; G Maier; W Landau; M A Beard
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

6.  Utility of anaerobic medium in pediatric blood cultures.

Authors:  M E Weisse
Journal:  Pediatr Infect Dis J       Date:  1994-09       Impact factor: 2.129

7.  Assessing the need for anaerobic medium for the recovery of clinically significant blood culture isolates in children.

Authors:  W M Dunne; J Tillman; P L Havens
Journal:  Pediatr Infect Dis J       Date:  1994-03       Impact factor: 2.129

8.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

9.  Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems.

Authors:  P Zwadyk; C L Pierson; C Young
Journal:  J Clin Microbiol       Date:  1994-05       Impact factor: 5.948

10.  Effect of iodophor vs iodine tincture skin preparation on blood culture contamination rate.

Authors:  C L Strand; R R Wajsbort; K Sturmann
Journal:  JAMA       Date:  1993-02-24       Impact factor: 56.272

View more
  2 in total

1.  Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT.

Authors:  K K Krisher; P Gibb; S Corbett; D Church
Journal:  J Clin Microbiol       Date:  2001-08       Impact factor: 5.948

2.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

  2 in total