Abstract

There are 3 definitions of acetabular version: true (anatomic) version, planar (radiographic) version, and operative version. Although planar version can be measured on standard radiographs, the measurement may be inaccurate when applied to metal-backed acetabular components. However, another version angle is depicted clearly on an angled, cross-table lateral radiograph of the hip--the axiolateral view, and this angle readily distinguishes anteversion from retroversion. If the angle of the xray beam is known or is standardized, version measured on the axiolateral view can be converted to the other version angles. Nomograms for these conversions are presented. In most cases, acetabular version measured on the axiolateral radiograph closely approximates planar version.

Mesh:

Year:  1995        PMID: 7634693

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

2.  Multilevel measurement of acetabular version using 3-D CT-generated models: implications for hip preservation surgery.

Authors:  Aimee C Perreira; John C Hunter; Thaddeus Laird; Amir A Jamali
Journal:  Clin Orthop Relat Res       Date:  2010-09-25       Impact factor: 4.176

3.  A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

Authors:  Mehmet Aydogan; Halil Burç; Gursel Saka
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

4.  The learning curve for adopting hip resurfacing among hip specialists.

Authors:  Ryan M Nunley; Jinjun Zhu; Peter J Brooks; C Anderson Engh; Stephen J Raterman; John S Rogerson; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

5.  Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Aleksi Reito; Timo Puolakka; Antti Paakkala; Jorma Pajamäki
Journal:  Int Orthop       Date:  2011-08-12       Impact factor: 3.075

6.  A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol.

Authors:  Varun Arora; Richard Hannan; Richard Beaver; Timothy Fletcher; Paul Harvie
Journal:  Skeletal Radiol       Date:  2016-11-08       Impact factor: 2.199

7.  Does stem design influence component positioning in total hip arthroplasty using a minimal invasive posterolateral approach?

Authors:  Wenzel Waldstein; Christian Merle; Tom Schmidt-Braekling; Friedrich Boettner
Journal:  Int Orthop       Date:  2014-03-07       Impact factor: 3.075

8.  Cross table lateral radiography for measurement of acetabular cup version.

Authors:  Olav Reikeras; Ragnhild Beate Gunderson
Journal:  Ann Transl Med       Date:  2016-05

9.  How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?

Authors:  Jaime A Carvajal Alba; Heather K Vincent; Jagdeep S Sodhi; Loren L Latta; Hari K Parvataneni
Journal:  Iowa Orthop J       Date:  2017

10.  CT outperforms radiography for determination of acetabular cup version after THA.

Authors:  Bernard Ghelman; Christopher K Kepler; Stephen Lyman; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.