A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

Mehmet Aydogan1, Halil Burç, Gursel Saka.   

Abstract

OBJECTIVE: Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip.
MATERIALS AND METHODS: The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula.
RESULTS: The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1.
CONCLUSION: Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

Entities:  

Mesh:

Year:  2013        PMID: 24253955     DOI: 10.1007/s00590-013-1353-4

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  20 in total

1.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

2.  Arthroplasty of the hip. A new operation.

Authors:  J Charnley
Journal:  Lancet       Date:  1961-05-27       Impact factor: 79.321

3.  A more reliable method to assess acetabular component position.

Authors:  John V Tiberi; Nicholas Pulos; Michael Kertzner; Thomas P Schmalzried; Thomas P Schmlazried
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Accuracy of intraoperative assessment of acetabular prosthesis placement.

Authors:  D M Hassan; G H Johnston; W N Dust; G Watson; A T Dolovich
Journal:  J Arthroplasty       Date:  1998-01       Impact factor: 4.757

5.  Radiographic localization of the acetabular component of a hip prosthesis.

Authors:  B Ghelman
Journal:  Radiology       Date:  1979-02       Impact factor: 11.105

6.  A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component.

Authors:  J D Visser; J G Konings
Journal:  J Bone Joint Surg Br       Date:  1981

7.  Radiologic evaluation of painful joint prostheses.

Authors:  R Schneider; R H Freiberger; B Ghelman; C S Ranawat
Journal:  Clin Orthop Relat Res       Date:  1982-10       Impact factor: 4.176

8.  Dislocation after total hip arthroplasty. Causes and prevention.

Authors:  D E McCollum; W J Gray
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

9.  The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning.

Authors:  M Maruyama; J R Feinberg; W N Capello; J A D'Antonio
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

10.  The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment.

Authors:  A M DiGioia; B Jaramaz; M Blackwell; D A Simon; F Morgan; J E Moody; C Nikou; B D Colgan; C A Aston; R S Labarca; E Kischell; T Kanade
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

View more
  1 in total

1.  The geometry of the bone structure associated with total hip arthroplasty.

Authors:  Zhang Yang; Wang Jian; Zhi-han Li; Xiao Jun; Zhao Liang; Yan Ge; Zhan-jun Shi
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.