Literature DB >> 7615323

In vivo vertical forces on implants.

E J Richter1.   

Abstract

Vertical forces applied to dental implants during oral functions have not been quantified precisely. The key problem has been the lack of suitable measuring devices. This article introduces a new technique for placing a transducer directly in the implant without any increase in vertical dimension. Results were compared to loads applied to teeth. Implants in the molar position that were fixed to a premolar with a prosthesis withstood maximum vertical forces of 60 to 120 N during chewing. Single molars and premolars carried maximum vertical forces of 120 to 150 N. Clenching in centric occlusion caused a load level of approximately 50 N for both natural and artificial abutments. Occlusal prematurities on the implant restoration that were less than 200 microns in height showed no significant increase of the implant load level.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7615323

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  15 in total

1.  Influence of Implant Surface Topography and Loading Condition on Stress Distribution in Bone Around Implants: A Comparative 3D FEA.

Authors:  Ravindra C Savadi; Jatin Agarwal; Rolly Shrivastava Agarwal; V Rangarajan
Journal:  J Indian Prosthodont Soc       Date:  2011-10-19

2.  Evaluation of fracture strength for single crowns made of the different types of lithium disilicate glass-ceramics.

Authors:  Chung-Ha Lim; Yong-Seok Jang; Min-Ho Lee; Tae-Sung Bae
Journal:  Odontology       Date:  2019-09-28       Impact factor: 2.634

3.  Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants.

Authors:  F J Gil; M Herrero-Climent; P Lázaro; J V Rios
Journal:  J Mater Sci Mater Med       Date:  2014-04-10       Impact factor: 3.896

4.  Sinking and fit of abutment of locking taper implant system.

Authors:  Seung-Jin Moon; Hee-Jung Kim; Mee-Kyoung Son; Chae-Heon Chung
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

5.  Experimentally determined mechanical properties of, and models for, the periodontal ligament: critical review of current literature.

Authors:  Ted S Fill; Jason P Carey; Roger W Toogood; Paul W Major
Journal:  J Dent Biomech       Date:  2011-04-05

6.  Quantitative evaluation by glucose diffusion of microleakage in aged calcium silicate-based open-sandwich restorations.

Authors:  S Koubi; H Elmerini; G Koubi; H Tassery; J Camps
Journal:  Int J Dent       Date:  2011-12-12

7.  A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments.

Authors:  Ji-Man Park; Jai-Bong Lee; Seong-Joo Heo; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

8.  Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.

Authors:  Ki-Joon Yoon; Young-Bum Park; Hyunmin Choi; Youngsung Cho; Jae-Hoon Lee; Keun-Woo Lee
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

9.  Comparative Evaluation of Implant Designs: Influence of Diameter, Length, and Taper on Stress and Strain in the Mandibular Segment-A Three-Dimensional Finite Element Analysis.

Authors:  Gowthama Raaj; Pulliappan Manimaran; Chandran Dhinesh Kumar; Duraisamy Sai Sadan; Mathivanan Abirami
Journal:  J Pharm Bioallied Sci       Date:  2019-05

10.  Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

Authors:  Hye Won Shim; Byoung-Eun Yang
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.