Literature DB >> 7609716

X-ray imaging using amorphous selenium: inherent spatial resolution.

W Que1, J A Rowlands.   

Abstract

This is a theoretical study of the inherent spatial resolution of the latent image on the surface of an amorphous selenium (a-Se) plate used for diagnostic x-ray imaging. The following effects are considered: (A) ranges of primary photoelectrons; (B) reabsorption of K fluorescence; (C) reabsorption of Compton scattered photons; (D) diffusion; (E) the geometric effect due to oblique incidence of x rays; (F) electrostatic effect; and (G) the space charge effect. The modulation transfer function of a-Se in the diagnostic x-ray energy range has been estimated. In conclusion, (A) and (E) are the main factors limiting the resolution, and for diagnostic x rays, the inherent spatial resolution of a-Se plates is much better than that of CsI layers used in x-ray image intensifiers.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7609716     DOI: 10.1118/1.597471

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Effect of repeated x-ray exposure on the resolution of amorphous selenium based x-ray imagers.

Authors:  M Z Kabir; L Chowdhury; G DeCrescenzo; O Tousignant; S O Kasap; J A Rowlands
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

3.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

4.  Oblique reconstructions in tomosynthesis. II. Super-resolution.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

5.  The x-ray light valve: a low-cost, digital radiographic imaging system--spatial resolution.

Authors:  Robert D MacDougall; Ivaylo Koprinarov; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

6.  Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

8.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

Review 9.  Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

Authors:  M M Wronski; J A Rowlands
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

10.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.