Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Joyoni Dey1.   

Abstract

SPECT is primarily used in the clinic for cardiac myocardial perfusion imaging. However, for SPECT, sensitivity is impaired due to the need for collimation. System resolution FWHM is poor as well (~ 1 cm). In this work the resolution of a curved detector was theoretically derived. The advantage of a curved detector over a flat detector with pinhole collimation was demonstrated for cardiac applications using theoretical derivations as well as a ray-tracing voxel-based forward projector. For the flat detector using parameters close to what was expected for the new multi-pinhole GE Discovery system, it is shown that using a paraboloid detector one may obtain a better system resolution (about 29% better on the average), keeping same pinhole opening. Alternately, sensitivity gains of as much as 2.25 may be obtained, for similar resolutions as a flat detector by just using a different pinhole with higher hole-diameter.

Entities:  

Keywords:  Curved detectors; Dedicated Cardiac SPECT; multi-pinhole

Year:  2012        PMID: 32952207      PMCID: PMC7495883          DOI: 10.1109/tns.2011.2182660

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  20 in total

1.  A novel approach to multipinhole SPECT for myocardial perfusion imaging.

Authors:  Tobias Funk; Dennis L Kirch; John E Koss; Elias Botvinick; Bruce H Hasegawa
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

2.  A multipinhole small animal SPECT system with submillimeter spatial resolution.

Authors:  Tobias Funk; Philippe Després; William C Barber; Kanai S Shah; Bruce H Hasegawa
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

3.  A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.

Authors:  Sanjiv S Gambhir; Daniel S Berman; Jack Ziffer; Michael Nagler; Martin Sandler; Jim Patton; Brian Hutton; Tali Sharir; Shlomo Ben Haim; Simona Ben Haim
Journal:  J Nucl Med       Date:  2009-04       Impact factor: 10.057

4.  An optimal rotator for iterative reconstruction.

Authors:  J W Wallis; T R Miller
Journal:  IEEE Trans Med Imaging       Date:  1997-02       Impact factor: 10.048

5.  U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.

Authors:  Freek J Beekman; Frans van der Have; Brendan Vastenhouw; Annemarie J A van der Linden; Peter P van Rijk; J Peter H Burbach; Marten P Smidt
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

6.  A low-energy multihole converging collimator compared with a pinhole collimator.

Authors:  R A Moyer
Journal:  J Nucl Med       Date:  1974-02       Impact factor: 10.057

7.  X-ray imaging using amorphous selenium: inherent spatial resolution.

Authors:  W Que; J A Rowlands
Journal:  Med Phys       Date:  1995-04       Impact factor: 4.071

8.  Two algorithms for use with an orthogonal-view coded-aperture system.

Authors:  R G Paxman; W E Smith; H H Barrett
Journal:  J Nucl Med       Date:  1984-06       Impact factor: 10.057

9.  U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging.

Authors:  Frans van der Have; Brendan Vastenhouw; Ruud M Ramakers; Woutjan Branderhorst; Jens O Krah; Changguo Ji; Steven G Staelens; Freek J Beekman
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

10.  Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners.

Authors:  Frank P Difilippo
Journal:  Phys Med Biol       Date:  2008-07-17       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.