Literature DB >> 7593921

Electrode ranking of "place pitch" and speech recognition in electrical hearing.

D A Nelson1, D J Van Tasell, A C Schroder, S Soli, S Levine.   

Abstract

The ability to distinguish electrical stimulation of different electrodes on the basis of "pitch or sharpness" was evaluated with an electrode ranking procedure in 14 individual users of the Nucleus cochlear implant. Prior to the electrode ranking test, absolute thresholds and maximum comfortable loudness levels were measured, and loudness balancing was accomplished across all usable electrodes. Performance on the electrode ranking task was defined in terms of d' per mm of distance between comparison electrodes. Large individual differences were found among cochlear-implant users. In subjects with good to excellent place-pitch sensitivity, the electrode ranking task was limited by a ceiling effect; however, in those with poor to moderate sensitivity d'/mm was relatively constant with spatial separation between electrodes. Place pitch was typically ordered from apical to basal electrodes, i.e., basal electrodes were judged to be higher in pitch than more apical electrodes. However, instances of reversals in place-pitch ordering were seen on some electrodes in some subjects. Instances were also seen of better electrode ranking in the apical half of the electrode array than in the basal half, and vice-versa. Analyses of the electrode ranking functions in terms of d' per stimulus indicated that, in some subjects, perfect performance was reached with as little as 0.75 mm between comparison electrodes, the minimum possible. In other subjects, perfect performance was not reached until the spatial separation between comparison electrodes was over 13 mm, more than three quarters of the entire length of the electrode array. Ten of the subjects also participated in a closed-set recognition task of intervocalic consonants. Although the maximum transmitted information for place of consonant articulation (which is based primarily on spectral speech cues) was only 34%, correlations between place-pitch sensitivity and transmitted speech information were as high as 0.71. This was surprising considering the excellent place-pitch sensitivity exhibited by some of the subjects, and may reflect limitations of the Nucleus speech coding strategy for representing spectrally coded speech information. The two prelingual subjects performed notably poorer on the speech task than the postlingual subjects, even though one of the prelingual subjects demonstrated very good place-pitch sensitivity.

Entities:  

Mesh:

Year:  1995        PMID: 7593921     DOI: 10.1121/1.413317

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  38 in total

1.  Perceptual "vowel spaces" of cochlear implant users: implications for the study of auditory adaptation to spectral shift.

Authors:  J D Harnsberger; M A Svirsky; A R Kaiser; D B Pisoni; R Wright; T A Meyer
Journal:  J Acoust Soc Am       Date:  2001-05       Impact factor: 1.840

2.  Multichannel place pitch sensitivity in cochlear implant recipients.

Authors:  Johan Laneau; Jan Wouters
Journal:  J Assoc Res Otolaryngol       Date:  2004-05-27

3.  Encoding pitch contours using current steering.

Authors:  Xin Luo; David M Landsberger; Monica Padilla; Arthi G Srinivasan
Journal:  J Acoust Soc Am       Date:  2010-09       Impact factor: 1.840

4.  Assessment of Spectral and Temporal Resolution in Cochlear Implant Users Using Psychoacoustic Discrimination and Speech Cue Categorization.

Authors:  Matthew B Winn; Jong Ho Won; Il Joon Moon
Journal:  Ear Hear       Date:  2016 Nov/Dec       Impact factor: 3.570

5.  Effects of Age and Cochlear Implantation on Spectrally Cued Speech Categorization.

Authors:  Mishaela DiNino; Julie G Arenberg; Anne L R Duchen; Matthew B Winn
Journal:  J Speech Lang Hear Res       Date:  2020-06-18       Impact factor: 2.297

6.  Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation.

Authors:  Russell L Snyder; Julie A Bierer; John C Middlebrooks
Journal:  J Assoc Res Otolaryngol       Date:  2004-08-12

7.  Implications of deep electrode insertion on cochlear implant fitting.

Authors:  Mathieu Gani; Gregory Valentini; Alain Sigrist; Maria-Izabel Kós; Colette Boëx
Journal:  J Assoc Res Otolaryngol       Date:  2007-01-11

8.  Spectral-ripple resolution correlates with speech reception in noise in cochlear implant users.

Authors:  Jong Ho Won; Ward R Drennan; Jay T Rubinstein
Journal:  J Assoc Res Otolaryngol       Date:  2007-06-21

9.  A relation between electrode discrimination and amplitude modulation detection by cochlear implant listeners.

Authors:  Monita Chatterjee; Jian Yu
Journal:  J Acoust Soc Am       Date:  2010-01       Impact factor: 1.840

Review 10.  Trends in cochlear implants.

Authors:  Fan-Gang Zeng
Journal:  Trends Amplif       Date:  2004
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.