Literature DB >> 23142466

Toxicodynamics of rigid polystyrene microparticles on pulmonary gas exchange in mice: implications for microemboli-based drug delivery systems.

H L Kutscher1, D Gao, S Li, C B Massa, J Cervelli, M Deshmukh, L B Joseph, D L Laskin, P J Sinko.   

Abstract

The toxicodynamic relationship between the number and size of pulmonary microemboli resulting from uniformly sized, rigid polystyrene microparticles (MPs) administered intravenously and their potential effects on pulmonary gas exchange were investigated. CD-1 male mice (6-8 weeks) were intravenously administered 10, 25 and 45 μm diameter MPs. Oxygen hemoglobin saturation in the blood (SpO(2)) was measured non-invasively using a pulse oximeter while varying inhaled oxygen concentration (F(I)O(2)). The resulting data were fit to a physiologically based non-linear mathematical model that estimates 2 parameters: ventilation-perfusion ratio (V(A)/Q) and shunt (percentage of deoxygenated blood returning to systemic circulation). The number of MPs administered prior to a statistically significant reduction in normalized V(A)/Q was dependent on particle size. MP doses that resulted in a significant reduction in normalized V(A)/Q one day post-treatment were 4000, 40,000 and 550,000 MPs/g for 45, 25 and 10 μm MPs, respectively. The model estimated V(A)/Q and shunt returned to baseline levels 7 days post-treatment. Measuring SpO(2) alone was not sufficient to observe changes in gas exchange; however, when combined with model-derived V(A)/Q and shunt early reversible toxicity from pulmonary microemboli was detected suggesting that the model and physical measurements are both required for assessing toxicity. Moreover, it appears that the MP load required to alter gas exchange in a mouse prior to lethality is significantly higher than the anticipated required MP dose for effective drug delivery. Overall, the current results indicate that the microemboli-based approach for targeted pulmonary drug delivery is potentially safe and should be further explored.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23142466      PMCID: PMC3586786          DOI: 10.1016/j.taap.2012.10.021

Source DB:  PubMed          Journal:  Toxicol Appl Pharmacol        ISSN: 0041-008X            Impact factor:   4.219


  19 in total

1.  Distribution of ventilation/perfusion ratios in pulmonary embolism: an adjunct to the interpretation of ventilation/perfusion lung scans.

Authors:  Emmanuel Itti; Séverine Nguyen; Fabrice Robin; Serge Desarnaud; Jean Rosso; Alain Harf; Michel Meignan
Journal:  J Nucl Med       Date:  2002-12       Impact factor: 10.057

2.  Determination of regional VA/Q by hyperpolarized 3He MRI.

Authors:  Rahim R Rizi; James E Baumgardner; Masaru Ishii; Zebulon Z Spector; Johan M Edvinsson; Aman Jalali; Jiangsheng Yu; Maxim Itkin; David A Lipson; Warren Gefter
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

3.  Proteomics of microparticles after experimental pulmonary embolism.

Authors:  John A Watts; Yong-Yook Lee; Michael A Gellar; Mary-Beth K Fulkerson; Sun-Ii Hwang; Jeffrey A Kline
Journal:  Thromb Res       Date:  2011-10-19       Impact factor: 3.944

4.  Relation between PaO2/FIO2 ratio and FIO2: a mathematical description.

Authors:  Jerome Aboab; Bruno Louis; Bjorn Jonson; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-08-09       Impact factor: 17.440

5.  Strain differences in response to acute hypoxia: CD-1 versus C57BL/6J mice.

Authors:  Charles F Zwemer; Michael Y Song; Katari A Carello; Louis G D'Alecy
Journal:  J Appl Physiol (1985)       Date:  2006-08-17

6.  Modelling of hypoxaemia after gynaecological laparotomy.

Authors:  S Kjaergaard; S E Rees; J A Nielsen; M Freundlich; P Thorgaard; S Andreassen
Journal:  Acta Anaesthesiol Scand       Date:  2001-03       Impact factor: 2.105

7.  Regional VA, Q, and VA/Q during PLV: effects of nitroprusside and inhaled nitric oxide.

Authors:  R Scott Harris; Donna-Beth Willey-Courand; C Alvin Head; Gaetano G Galletti; Daniel M Call; José G Venegas
Journal:  J Appl Physiol (1985)       Date:  2002-01

8.  Use of allometry in predicting anatomical and physiological parameters of mammals.

Authors:  S L Lindstedt; P J Schaeffer
Journal:  Lab Anim       Date:  2002-01       Impact factor: 2.471

9.  The PIO2 vs. SpO2 diagram: a non-invasive measure of pulmonary oxygen exchange.

Authors:  D J Sapsford; J G Jones
Journal:  Eur J Anaesthesiol       Date:  1995-07       Impact factor: 4.330

10.  Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance.

Authors:  Dan S Karbing; Søren Kjaergaard; Bram W Smith; Kurt Espersen; Charlotte Allerød; Steen Andreassen; Stephen E Rees
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

View more
  4 in total

1.  In vivo evidence of methamphetamine induced attenuation of brain tissue oxygenation as measured by EPR oximetry.

Authors:  John Weaver; Yirong Yang; Rebecca Purvis; Theodore Weatherwax; Gerald M Rosen; Ke Jian Liu
Journal:  Toxicol Appl Pharmacol       Date:  2014-01-08       Impact factor: 4.219

Review 2.  Pharmaceutical and toxicological properties of engineered nanomaterials for drug delivery.

Authors:  Matthew Palombo; Manjeet Deshmukh; Daniel Myers; Jieming Gao; Zoltan Szekely; Patrick J Sinko
Journal:  Annu Rev Pharmacol Toxicol       Date:  2013-10-23       Impact factor: 13.820

3.  Using a non-invasive assessment of lung injury in a murine model of acute lung injury.

Authors:  Siân Lax; Michael R Wilson; Masao Takata; David R Thickett
Journal:  BMJ Open Respir Res       Date:  2014-01-03

4.  A biodegradable nanoparticle platform for the induction of antigen-specific immune tolerance for treatment of autoimmune disease.

Authors:  Zoe Hunter; Derrick P McCarthy; Woon Teck Yap; Christopher T Harp; Daniel R Getts; Lonnie D Shea; Stephen D Miller
Journal:  ACS Nano       Date:  2014-02-27       Impact factor: 15.881

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.