Pacemaker failure induced by radiotherapy.

S K Souliman1, J Christie.   

Abstract

It is well documented that radiation therapy can have significant transitory and permanent effects on the function of cardiac pacemakers. In this study 18 multiprogrammable pacemakers were tested to establish any pattern by which these pacemakers are affected. The results confirm previous predictions on how pacemakers are damaged. The damage could be divided essentially into three types: (1) temporary change to interference or safety mode pacing lasting for the duration of the irradiation only; (2) change to interference mode pacing--from which recovery may occur after reprogramming the pacemaker; and (3) severe damage; in this case the pacemaker stops generating pulses. Recovery from this may occur a long time after the end of the treatment, but this recovery is mostly incomplete and the pacemaker cannot be used reliably thereafter. Therefore it is essential that patients with implanted pacemakers undergoing radiation therapy, should be monitored closely during the course of the treatment and for a few weeks thereafter.

Entities:  

Mesh:

Year:  1994        PMID: 7513850     DOI: 10.1111/j.1540-8159.1994.tb01387.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  15 in total

1.  Radiation tolerance of contemporary implantable cardioverter-defibrillators.

Authors:  Michael Mollerus; Leslee Naslund; Margaret Lipinski; Anne Meyer; Bruce Libey; Ken Dornfeld
Journal:  J Interv Card Electrophysiol       Date:  2013-12-07       Impact factor: 1.900

Review 2.  [Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations].

Authors:  M Dorenkamp; C Stromberger; C von Heymann; W Haverkamp; P Wust; M Roser
Journal:  Strahlenther Onkol       Date:  2012-11-11       Impact factor: 3.621

3.  Effect of X-ray dose rates higher than 8 Gy/min on the functioning of cardiac implantable electronic devices.

Authors:  Kazuhiko Nakamura; Takahiro Aoyama; Naoki Kaneda; Masashi Otsuji; Yoshitaka Minami; Ami Sakuragi; Masaru Nakamura
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

4.  Radiation dose monitoring in a breast cancer patient with a pacemaker: a case report.

Authors:  J R Nibhanupudy; M A de Jesus; M Fujita; A L Goldson
Journal:  J Natl Med Assoc       Date:  2001 Jul-Aug       Impact factor: 1.798

5.  Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects.

Authors:  Giulia Riva; Ombretta Alessandro; Ruggero Spoto; Annamaria Ferrari; Cristina Garibaldi; Federica Cattani; Rosa Luraschi; Elena Rondi; Nicola Colombo; Fulvio Lorenzo Francesco Giovenzana; Carlo Maria Cipolla; Mikolaj Winnicki; Martina Persiani; Fabiana Castelluccia; Massimo Sarra Fiore; Roberto Orecchia; Barbara Alicja Jereczek-Fossa
Journal:  Med Oncol       Date:  2018-04-17       Impact factor: 3.064

6.  DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices.

Authors:  Benjamin Gauter-Fleckenstein; Carsten W Israel; Marc Dorenkamp; Jürgen Dunst; Mattias Roser; Rainer Schimpf; Volker Steil; Jörg Schäfer; Ulrike Höller; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2015-03-05       Impact factor: 3.621

7.  Radiotherapy of patients with cardiac implantable electronic devices according to the DEGRO/DGK guideline-is the risk of relevant errors overestimated?

Authors:  Felix Steger; Matthias G Hautmann; Christoph Süß; Ute Hubauer; Ekrem Ücer; Lars Maier; Oliver Kölbl; Carsten Jungbauer
Journal:  Strahlenther Onkol       Date:  2019-08-09       Impact factor: 3.621

8.  Management and postoperative outcome in primary lung cancer and heart disease co-morbidity: a systematic review and meta-analysis.

Authors:  George D Bablekos; Antonis Analitis; Stylianos A Michaelides; Konstantinos A Charalabopoulos; Anastasia Tzonou
Journal:  Ann Transl Med       Date:  2016-06

9.  Implantable cardiac pacemaker failure by cumulative dose effects of flattening filter free beams.

Authors:  Kazuhiko Nakamura; Takahiro Aoyama; Naoki Kaneda; Masashi Otsuji; Yoshitaka Minami; Ami Sakuragi; Masaru Nakamura
Journal:  J Radiat Res       Date:  2021-07-10       Impact factor: 2.724

10.  Pacemaker and radiotherapy in breast cancer: is targeted intraoperative radiotherapy the answer in this setting?

Authors:  Mohammed Rs Keshtgar; David J Eaton; Claire Reynolds; Katharine Pigott; Tim Davidson; Benjamin Gauter-Fleckenstein; Frederik Wenz
Journal:  Radiat Oncol       Date:  2012-08-01       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.