Radiation dose monitoring in a breast cancer patient with a pacemaker: a case report.

J R Nibhanupudy1, M A de Jesus, M Fujita, A L Goldson.   

Abstract

A pacemaker-bearing patient with left-sided breast cancer was treated with adjuvant external beam radiation therapy to the intact breast. She was treated via tangential fields and a single anterior supraclavicular field using 6-MV x-rays. The pacemaker, originally in the treatment field, was removed and a new one placed 4 cm outside the radiation field prior to treatment. Silicon diode chamber Keithley-Farmer type 0.6 cc ionization chamber, and lithium fluoride (LiF) (TLD) chips were used to measure, in vivo, the dose to the pacemaker. From all the fields treated, total dose to the pacemaker was 164 cGy by diode measurements, 182 cGy by ionization chamber measurements, and 171 cGy by TLD measurements. The pacemaker functioned normally throughout the course of treatment.

Entities:  

Mesh:

Year:  2001        PMID: 11491279      PMCID: PMC2594037     

Source DB:  PubMed          Journal:  J Natl Med Assoc        ISSN: 0027-9684            Impact factor:   1.798


  9 in total

1.  The effects of cardiac pacemakers of ionizing radiation and electromagnetic interference from radiotherapy machines.

Authors:  J R Marbach; R T Meoz-Mendez; J K Huffman; P T Hudgins; P R Almond
Journal:  Int J Radiat Oncol Biol Phys       Date:  1978 Nov-Dec       Impact factor: 7.038

2.  Therapeutic irradiation over a permanent cardiac pacemaker.

Authors:  R J Teskey; I Whelan; Y Akyurekli; L Eapen; M S Green
Journal:  Pacing Clin Electrophysiol       Date:  1991-02       Impact factor: 1.976

3.  Monitoring the radiation dose to a multiprogrammable pacemaker during radical radiation therapy: a case report.

Authors:  R Muller-Runkel; G Orsolini; U P Kalokhe
Journal:  Pacing Clin Electrophysiol       Date:  1990-11       Impact factor: 1.976

4.  Pacemaker failure induced by radiotherapy.

Authors:  S K Souliman; J Christie
Journal:  Pacing Clin Electrophysiol       Date:  1994-03       Impact factor: 1.976

5.  Runaway atrioventricular sequential pacemaker after radiation therapy.

Authors:  R W Lee; S K Huang; E Mechling; I Bazgan
Journal:  Am J Med       Date:  1986-11       Impact factor: 4.965

6.  The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators.

Authors:  J L Venselaar
Journal:  Radiother Oncol       Date:  1985-01       Impact factor: 6.280

7.  Radiation induced failures of complementary metal oxide semiconductor containing pacemakers: a potentially lethal complication.

Authors:  A A Lewin; C F Serago; J G Schwade; A A Abitbol; S C Margolis
Journal:  Int J Radiat Oncol Biol Phys       Date:  1984-10       Impact factor: 7.038

8.  Pacemaker function during irradiation: in vivo and in vitro effect.

Authors:  S L Ngu; P O'Meley; N Johnson; C Collins
Journal:  Australas Radiol       Date:  1993-02

9.  Pacemaker failure associated with therapeutic radiation.

Authors:  C Brooks; M Mutter
Journal:  Am J Emerg Med       Date:  1988-11       Impact factor: 2.469

  9 in total
  4 in total

Review 1.  [Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations].

Authors:  M Dorenkamp; C Stromberger; C von Heymann; W Haverkamp; P Wust; M Roser
Journal:  Strahlenther Onkol       Date:  2012-11-11       Impact factor: 3.621

2.  DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices.

Authors:  Benjamin Gauter-Fleckenstein; Carsten W Israel; Marc Dorenkamp; Jürgen Dunst; Mattias Roser; Rainer Schimpf; Volker Steil; Jörg Schäfer; Ulrike Höller; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2015-03-05       Impact factor: 3.621

Review 3.  Medical factors influencing decision making regarding radiation therapy for breast cancer.

Authors:  Christina A Dilaveri; Nicole P Sandhu; Lonzetta Neal; Michelle A Neben-Wittich; Tina J Hieken; Maire Brid Mac Bride; Dietlind L Wahner-Roedler; Karthik Ghosh
Journal:  Int J Womens Health       Date:  2014-11-19

4.  A Monte Carlo and experimental investigation of the dosimetric behavior of low- and medium-perturbation diodes used for entrance in vivo dosimetry in megavoltage photon beams.

Authors:  Mohammad Amin Mosleh-Shirazi; Sareh Karbasi; Daryoush Shahbazi-Gahrouei; Shahram Monadi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.