Literature DB >> 29667046

Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects.

Giulia Riva1,2, Ombretta Alessandro1,2, Ruggero Spoto2, Annamaria Ferrari2, Cristina Garibaldi3, Federica Cattani4, Rosa Luraschi4, Elena Rondi4, Nicola Colombo5, Fulvio Lorenzo Francesco Giovenzana5, Carlo Maria Cipolla5, Mikolaj Winnicki6, Martina Persiani2, Fabiana Castelluccia2, Massimo Sarra Fiore2, Roberto Orecchia7, Barbara Alicja Jereczek-Fossa1,2.   

Abstract

As a result of aging, the number of patients with cardiac implantable electronic device (CIED) requiring radiotherapy (RT) continues to rise. The aim of this work was to evaluate RT-related malfunctions of CIED in a cohort of patients who underwent RT in our clinic from June 2010 to December 2016. We retrospectively analyzed 93 RT treatments in 63 patients with CIEDs. Patients were treated with 3D conformal RT, intensity-modulated RT and stereotactic RT. We collected clinical characteristics of cancer, models of CIEDs, total RT dose to tumor and radiation energy. Radiation dose delivered to CIED and its dysfunctions after RT was evaluated. Subgroup analysis of 48 RT treatments (32 patients) on chest and neck plus on 13 RT treatments (12 patients) with 18 MV neutron-producing photon energy considered as high risk was performed. The number of treatments of patients with CIEDs increased from 0.3% in 2011 to 1.2% in 2016. Two patients, treated with 18 MV photon beam, with implantable cardioverter-defibrillators (ICDs) that received a maximum dose of around 2.1 Gy, experienced adverse events: a reprogramming of ICD when the patient reached a delivered dose to the tumor of 32 Gy, and an altered sensing function requiring replacement after 11 months from the end of RT. Nearly 2% of patients with CIEDs from high-risk patients subgroup had experienced a damage of the device. Close cooperation between radiation oncologists, cardiologists, medical physicists and radiation technologists is needed to achieve the best practice management in these patients.

Entities:  

Keywords:  Cancer; Cardiac implantable electronic devices; Cardiac toxicity; Radiotherapy

Mesh:

Year:  2018        PMID: 29667046     DOI: 10.1007/s12032-018-1126-3

Source DB:  PubMed          Journal:  Med Oncol        ISSN: 1357-0560            Impact factor:   3.064


  23 in total

1.  Management of patients with implantable cardioverter defibrillator needing radiation therapy for cancer.

Authors:  M Langer; E Orlandi; M Carrara; P Previtali; E A Haeusler
Journal:  Br J Anaesth       Date:  2012-05       Impact factor: 9.166

2.  The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study.

Authors:  Tomas Zaremba; Annette Ross Jakobsen; Anna Margrethe Thøgersen; Lars Oddershede; Sam Riahi
Journal:  Europace       Date:  2013-08-09       Impact factor: 5.214

3.  The world survey of cardiac pacing and cardioverter-defibrillators: calendar year 2005 an International Cardiac Pacing and Electrophysiology Society (ICPES) project.

Authors:  Harry G Mond; Marleen Irwin; Hugo Ector; Alessandro Proclemer
Journal:  Pacing Clin Electrophysiol       Date:  2008-09       Impact factor: 1.976

Review 4.  2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices.

Authors:  Julia H Indik; J Rod Gimbel; Haruhiko Abe; Ricardo Alkmim-Teixeira; Ulrika Birgersdotter-Green; Geoffrey D Clarke; Timm-Michael L Dickfeld; Jerry W Froelich; Jonathan Grant; David L Hayes; Hein Heidbuchel; Salim F Idriss; Emanuel Kanal; Rachel Lampert; Christian E Machado; John M Mandrola; Saman Nazarian; Kristen K Patton; Marc A Rozner; Robert J Russo; Win-Kuang Shen; Jerold S Shinbane; Wee Siong Teo; William Uribe; Atul Verma; Bruce L Wilkoff; Pamela K Woodard
Journal:  Heart Rhythm       Date:  2017-05-11       Impact factor: 6.343

Review 5.  Effect of radiation therapy on the latest generation of pacemakers and implantable cardioverter defibrillators: A systematic review.

Authors:  F Hudson; D Coulshed; E D'Souza; C Baker
Journal:  J Med Imaging Radiat Oncol       Date:  2010-02       Impact factor: 1.735

6.  DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices.

Authors:  Benjamin Gauter-Fleckenstein; Carsten W Israel; Marc Dorenkamp; Jürgen Dunst; Mattias Roser; Rainer Schimpf; Volker Steil; Jörg Schäfer; Ulrike Höller; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2015-03-05       Impact factor: 3.621

7.  Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study.

Authors:  Tomas Zaremba; Annette Ross Jakobsen; Mette Søgaard; Anna Margrethe Thøgersen; Martin Berg Johansen; Laerke Bruun Madsen; Sam Riahi
Journal:  Pacing Clin Electrophysiol       Date:  2015-01-20       Impact factor: 1.976

8.  Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function.

Authors:  Akash Makkar; Joann Prisciandaro; Sunil Agarwal; Morgan Lusk; Laura Horwood; Jean Moran; Colleen Fox; James A Hayman; Hamid Ghanbari; Brett Roberts; Diego Belardi; Rakesh Latchamsetty; Thomas Crawford; Eric Good; Krit Jongnarangsin; Frank Bogun; Aman Chugh; Hakan Oral; Fred Morady; Frank Pelosi
Journal:  Heart Rhythm       Date:  2012-08-28       Impact factor: 6.343

Review 9.  Management of radiation therapy patients with cardiac defibrillator or pacemaker.

Authors:  Francesca Salerno; Sara Gomellini; Cristina Caruso; Raffaele Barbara; Daniela Musio; Tamara Coppi; Mario Cardinale; Vincenzo Tombolini; Ugo de Paula
Journal:  Radiol Med       Date:  2015-12-26       Impact factor: 3.469

10.  Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands. Dutch Society of Radiotherapy and Oncology (NVRO).

Authors:  Coen W Hurkmans; Joost L Knegjens; Bing S Oei; Ad J J Maas; G J Uiterwaal; Arnoud J van der Borden; Marleen M J Ploegmakers; Lieselot van Erven
Journal:  Radiat Oncol       Date:  2012-11-24       Impact factor: 3.481

View more
  6 in total

1.  Radiotherapy-induced malfunctions of cardiac implantable electronic devices in cancer patients.

Authors:  Vincenzo L Malavasi; Giuseppina De Marco; Jacopo F Imberti; Filippo Placentino; Marco Vitolo; Ercole Mazzeo; Gianfranco Cicoria; Edoardo Casali; Vincenzo Turco; Frank Lohr; Giuseppe Boriani
Journal:  Intern Emerg Med       Date:  2019-12-02       Impact factor: 3.397

2.  Stereotactic Radiotherapy Ablation and Atrial Fibrillation: Technical Issues and Clinical Expectations Derived From a Systematic Review.

Authors:  Jessica Franzetti; Stefania Volpe; Valentina Catto; Edoardo Conte; Consiglia Piccolo; Matteo Pepa; Gaia Piperno; Anna Maria Camarda; Federica Cattani; Daniele Andreini; Claudio Tondo; Barbara Alicja Jereczek-Fossa; Corrado Carbucicchio
Journal:  Front Cardiovasc Med       Date:  2022-05-03

Review 3.  A Review and Analysis of Managing Commonly Seen Implanted Devices for Patients Undergoing Radiation Therapy.

Authors:  Maria F Chan; Claire Young; Daphna Gelblum; Chengyu Shi; Carolanne Rincon; Elizabeth Hipp; Jingdong Li; Dongxu Wang
Journal:  Adv Radiat Oncol       Date:  2021-08-06

4.  Local dose rate effects in implantable cardioverter-defibrillators with flattening filter free and flattened photon radiation.

Authors:  Benjamin Gauter-Fleckenstein; Erol Tülümen; Boris Rudic; Martin Borggrefe; Martin Polednik; Jens Fleckenstein
Journal:  Strahlenther Onkol       Date:  2022-03-10       Impact factor: 4.033

5.  STRA-MI-VT (STereotactic RadioAblation by Multimodal Imaging for Ventricular Tachycardia): rationale and design of an Italian experimental prospective study.

Authors:  C Carbucicchio; B A Jereczek-Fossa; D Andreini; V Catto; G Piperno; E Conte; F Cattani; E Rondi; S Vigorito; C Piccolo; A Bonomi; A Gorini; M Pepa; S Mushtaq; G Fassini; M Moltrasio; F Tundo; G Marvaso; F Veglia; R Orecchia; E Tremoli; C Tondo
Journal:  J Interv Card Electrophysiol       Date:  2020-08-27       Impact factor: 1.900

Review 6.  The impact of particle radiotherapy on the functioning of cardiac implantable electronic devices: a systematic review of in vitro and in vivo studies according to PICO criteria.

Authors:  Amelia Barcellini; Veronica Dusi; Alfredo Mirandola; Sara Ronchi; Giulia Riva; Francesca Dal Mas; Maurizio Massaro; Viviana Vitolo; Mario Ciocca; Roberto Rordorf; Ester Orlandi
Journal:  Radiol Med       Date:  2022-07-24       Impact factor: 6.313

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.