Literature DB >> 7484121

Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients.

H Malchau1, J Kärrholm, Y X Wang, P Herberts.   

Abstract

We assessed the accuracy of migration measurements on conventional and digitized radiographs of total hip arthroplasties by comparing the results with radiostereometry (RSA). 4 stem and 3 acetabular designs were studied. 2 of the stem designs and 1 cup design were uncemented. 180 manual and 202 digitized measurements were done on 120 conventional radiographic examinations. The readings on digitized radiographs did not differ from the manual measurements on the same radiographs. A comparison of the measurements from plain radiographs and with RSA of the femoral stems revealed an accuracy (absolute mean + 2 SD) of between 3.9 and 12.3 mm, depending on the choice of landmarks. The greatest accuracy was obtained by using tantalum markers inserted into the greater or the lesser trochanter and the shoulder of the stem. The most medial point of the lesser trochanter proved to be the best bony landmark. Measurements, including both the center of the femoral head and the greater trochanter, were associated with poor accuracy. The accuracy as regards horizontal cup migration varied from 4.4 to 6.5 mm and the accuracy as regards vertical migration varied between 4.4 and 6.3 mm. The intraobserver error (2 SD) ranged from 1.6 mm to 5.6 mm, The corresponding figures for the inter-observer error were 2.6 mm and 6.6 mm, respectively. One of the cemented cup designs was associated with inferior accuracy. Stem design did not affect the accuracy.

Entities:  

Mesh:

Year:  1995        PMID: 7484121     DOI: 10.3109/17453679508995578

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  43 in total

1.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

2.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

3.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

4.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

5.  Case report: Cementless stem stabilization after intraoperative fracture: a radiostereometric analysis.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2009-09-17       Impact factor: 4.176

6.  Partial weightbearing is not necessary after cementless total hip arthroplasty: a two-year prospective randomized study on 100 patients.

Authors:  Max Markmiller; Thomas Weiss; Peter Kreuz; Axel Rüter; Gerhard Konrad
Journal:  Int Orthop       Date:  2010-07-11       Impact factor: 3.075

7.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

8.  Tapered fluted titanium stems in the management of Vancouver B2 and B3 periprosthetic femoral fractures.

Authors:  Jacob T Munro; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

9.  Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem.

Authors:  H Wangen; P Lereim; I Holm; R Gunderson; O Reikerås
Journal:  Int Orthop       Date:  2007-02-15       Impact factor: 3.075

10.  Large femoral bone loss after hip revision using the uncemented proximally porous-coated Bi-Metric prosthesis: 22 hips followed for a mean of 6 years.

Authors:  Per Y Adolphson; Mats O F Salemyr; Olof G Sköldenberg; Henrik S G Bodén
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.