Quality assessment of blood glucose monitors in use outside the hospital laboratory.

R F Drucker, D R Williams, C P Price.   

Abstract

The quality of analytical results required in clinical practice is generally dictated by analytical rather than clinical criteria. The increasing availability of analytical technology that can be used outside the hospital laboratory challenges this situation. In an attempt to highlight this dilemma one method of glucose analysis outside the laboratory has been assessed using a pilot external quality assessment scheme (EQAS) and the results have been compared with the performance of the same machines in the laboratory. In the laboratory reliable results were obtained when the Glucometer was used by experienced laboratory personnel giving a good correlation of results (r = 0.96) when compared with an automated method. The results of the EQAS revealed that 44% of hospital ward glucose estimations and 63% of general practice estimations would be considered unsatisfactory by conventional laboratory criteria--that is, greater than +/- 2 SD of the mean laboratory result. This level of performance must, however, be considered in relation to the number of times that a clinically misleading result is obtained. No analytical system should be used in clinical practice without a continuous, objective assessment of its performance.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6875021      PMCID: PMC498428          DOI: 10.1136/jcp.36.8.948

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  12 in total

1.  Performance of blood-glucose strips.

Authors:  R Worth; D G Johnston; J Anderson; K G Alberti
Journal:  Lancet       Date:  1979-10-06       Impact factor: 79.321

2.  Automated fluorometric micromethod for blood glucose.

Authors:  C W Seiter; H D Hill; G K Summer
Journal:  Clin Chem       Date:  1973-11       Impact factor: 8.327

3.  Towards a target blood-glucose in diabetes.

Authors:  R J Jarrett; H Keen
Journal:  Lancet       Date:  1980-07-05       Impact factor: 79.321

4.  Home monitoring of blood glucose using filter paper strips.

Authors:  R Paisey; P Bradshaw; M Hartog; P West
Journal:  Br Med J       Date:  1979-12-08

5.  Performance of blood-glucose meters.

Authors:  L J Borthwick; I S Ross
Journal:  Lancet       Date:  1979-04-28       Impact factor: 79.321

6.  Performance of blood-glucose analysers.

Authors:  E F Legg; H G Sammons
Journal:  Lancet       Date:  1979-06-02       Impact factor: 79.321

7.  Performance of home blood-glucose meters.

Authors:  J L Day; A G Archer; J Metcalfe
Journal:  Lancet       Date:  1979-07-07       Impact factor: 79.321

8.  Monitoring blood glucose.

Authors:  A H Knight
Journal:  Br Med J       Date:  1980-01-26

9.  Measurement of capillary blood glucose in filter-paper spots: an aid to the assessment of diabetic control.

Authors:  K Wakelin; D J Goldie; M Hartog; A P Robinson
Journal:  Br Med J       Date:  1978-08-12

10.  Blood glucose monitors: a laboratory and patient assessment.

Authors:  D J Webb; J M Lovesay; A Ellis; A H Knight
Journal:  Br Med J       Date:  1980-02-09
View more
  9 in total

1.  Stick testing.

Authors:  V Marks
Journal:  BMJ       Date:  1991-03-02

2.  Laboratory medicine in primary health care.

Authors:  P M Broughton
Journal:  Br J Gen Pract       Date:  1990-01       Impact factor: 5.386

3.  Laboratory assessment of three reflectance meters designed for self monitoring of blood glucose concentrations.

Authors:  J P Begley; A R Forrest
Journal:  J Clin Pathol       Date:  1988-04       Impact factor: 3.411

4.  Quality of plasma cholesterol measurements in primary care.

Authors:  P M Broughton; D G Bullock; R Cramb
Journal:  BMJ       Date:  1989-02-04

5.  Evaluation of the quality of bedside monitoring of the blood glucose level in a teaching hospital.

Authors:  C Ting; A A Nanji
Journal:  CMAJ       Date:  1988-01-01       Impact factor: 8.262

6.  Diagnostic equipment outside the laboratory.

Authors:  J M Burrin; J A Fyffe
Journal:  J Clin Pathol       Date:  1988-09       Impact factor: 3.411

7.  Comparison of the use of a dry chemistry analyser in primary care in Norway and the United Kingdom.

Authors:  G Thue; S Sandberg; D G Bullock
Journal:  Br J Gen Pract       Date:  1993-01       Impact factor: 5.386

8.  Rapid measurement of creatine kinase activity in a coronary care unit using a portable benchtop reflectance photometer.

Authors:  I Gibb; J R Barton; P C Adams; D Pratt; C R Dean; I F Tarbit
Journal:  Br Med J (Clin Res Ed)       Date:  1985-05-11

9.  Interval between insulin injection and eating in relation to blood glucose control in adult diabetics.

Authors:  M E Lean; L L Ng; B R Tennison
Journal:  Br Med J (Clin Res Ed)       Date:  1985-01-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.