Rapid measurement of creatine kinase activity in a coronary care unit using a portable benchtop reflectance photometer.

I Gibb, J R Barton, P C Adams, D Pratt, C R Dean, I F Tarbit.   

Abstract

Rapid measurements of plasma creatine kinase activity using an inexpensive benchtop reflectance photometer (Ames Seralyzer) and disposable reagent strips were evaluated in the laboratory and coronary care unit. The system proved simple to use and capable of yielding rapid (four minutes per analysis), precise (coefficient of variation less than 9%), and accurate results (correlation with routine method 0.995) when used by medical staff. Creatine kinase values were available 6.5-102 hours earlier than routine laboratory data, depending on the time and day of sampling, thereby facilitating appropriate and economic patient management. This instrument might be used to supplement the routine enzyme service for selected admissions, resulting in greatly improved availability of results and hence contributing to the early discharge of patients from intensive care facilities.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3922502      PMCID: PMC1415631          DOI: 10.1136/bmj.290.6479.1381

Source DB:  PubMed          Journal:  Br Med J (Clin Res Ed)        ISSN: 0267-0623


  7 in total

1.  Effect of light and temperature on the stability of creatine kinase in human sera and controls.

Authors:  B Perry; B Doumas; B Jendrzejczak
Journal:  Clin Chem       Date:  1979-04       Impact factor: 8.327

2.  Measurement of the enzymes lactate dehydrogenase and creatine kinase using reflectance spectroscopy and reagent strips.

Authors:  J F Stevens; W Tsang; R G Newall
Journal:  J Clin Pathol       Date:  1983-12       Impact factor: 3.411

3.  Clinical biochemistry nearer the patient.

Authors:  V Marks
Journal:  Br Med J (Clin Res Ed)       Date:  1983-04-09

4.  Biochemists nearer the patient?

Authors:  S E Evans; B M Buckley
Journal:  Br Med J (Clin Res Ed)       Date:  1983-11-12

5.  Quality assessment of blood glucose monitors in use outside the hospital laboratory.

Authors:  R F Drucker; D R Williams; C P Price
Journal:  J Clin Pathol       Date:  1983-08       Impact factor: 3.411

6.  Multilayer film elements for clinical analysis: general concepts.

Authors:  H G Curme; R L Columbus; G M Dappen; T W Eder; W D Fellows; J Figueras; C P Glover; C A Goffe; D E Hill; W H Lawton; E J Muka; J E Pinney; R N Rand; K J Sanford; T W Wu
Journal:  Clin Chem       Date:  1978-08       Impact factor: 8.327

7.  Analytical investigations closer to the patient.

Authors:  D Watson
Journal:  Br Med J       Date:  1980-07-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.