Diagnostic equipment outside the laboratory.

J M Burrin1, J A Fyffe.   

Abstract

A questionnaire was circulated to clinical biochemistry laboratories in the North West Thames region of the United Kingdom requesting information on extralaboratory equipment. Data on the types and numbers of instruments in use, their relationship with the laboratory, and quality assurance procedures were obtained. Laboratories were prepared to maintain equipment over which they had no responsibility for purchase, training of users, or use. The quality assurance of these instruments gave even greater cause for concern. Although internal quality control procedures were performed on many of the instruments, laboratories were involved in only a minority of these procedures. Quality control procedures and training of users were undertaken on site in less than 50% of blood gas analysers and bilirubin meters and in less than 25% of glucose meters. External quality assessment procedures were non-existent for all of the instruments in use with the exception of glucose stick meters in two laboratories.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3192750      PMCID: PMC1141643          DOI: 10.1136/jcp.41.9.925

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  Stick testing: a cause for concern.

Authors:  J Fyffe
Journal:  Br J Hosp Med       Date:  1986-03

2.  Regional quality assessment of pH and blood gas analysers.

Authors:  D Burnett; R D Henfrey; T F Woods; J A Fyffe
Journal:  Ann Clin Biochem       Date:  1986-01       Impact factor: 2.057

3.  Guidelines on the performance of chemical pathology assays outside the laboratory.

Authors:  J R Anderson; W D Linsell; F M Mitchell
Journal:  Br Med J (Clin Res Ed)       Date:  1981-02-28

4.  Performance of a quality-assessment scheme for blood glucose meters in general practice.

Authors:  J M Burrin; D R Williams; C P Price
Journal:  Ann Clin Biochem       Date:  1985-03       Impact factor: 2.057

5.  Quality assessment of blood glucose monitors in use outside the hospital laboratory.

Authors:  R F Drucker; D R Williams; C P Price
Journal:  J Clin Pathol       Date:  1983-08       Impact factor: 3.411

  5 in total
  1 in total

1.  Evidence based practice: clinicians' use and attitudes to near patient testing in hospitals.

Authors:  T A Gray; D B Freedman; D Burnett; A Szczepura; C P Price
Journal:  J Clin Pathol       Date:  1996-11       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.