Literature DB >> 6867113

Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen--film systems.

H P Chan, K Doi.   

Abstract

The relationship between the film density and the x-ray energy absorbed in the screens, and the effect of the components of a screen--film system on x-ray absorption in the screen phosphor has been studied. It is concluded that, to a good approximation, the total absorbed x-ray energy can be calculated ignoring components other than the phosphor, and that the absorbed energy is related to the film density through the characteristic curve of the film. This simple relationship provides a basis for the theoretical prediction of the radiographic performance of an imaging system. Analytical expressions have been derived for the energy absorbed in model screens containing one or two high-atomic-number elements. For incident energies above the K-edge of the high-Z elements, the contribution of the K x-rays to energy absorption was included by use of a K-reabsorption factor. This factor was determined for eight screen pairs as a function of incident photon energy and incident angle.

Entities:  

Mesh:

Year:  1983        PMID: 6867113     DOI: 10.1088/0031-9155/28/5/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.

Authors:  Andrew T Kuhls; Girijesh Yadava; Vikas Patel; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007

4.  Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

Authors:  Qian Cao; Alejandro Sisniega; Michael Brehler; J Webster Stayman; John Yorkston; Jeffrey H Siewerdsen; Wojciech Zbijewski
Journal:  Med Phys       Date:  2017-11-27       Impact factor: 4.071

5.  Modeling the performance characteristics of computed radiography (CR) systems.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.