Modeling the performance characteristics of computed radiography (CR) systems.

Srinivasan Vedantham1, Andrew Karellas.   

Abstract

Computed radiography (CR) using storage phosphors is widely used in digital radiography and mammography. A cascaded linear systems approach wherein several parameter values were estimated using Monte Carlo methods was used to model the image formation process of a single-side read ;;flying spot'' CR system using a granular phosphor. Objective image quality metrics such as modulation transfer function and detective quantum efficiency were determined using this model and show good agreement with published empirical data. A model such as that addressed in this work could allow for improved understanding of the effect of storage phosphor physical properties and CR reader parameters on objective image quality metrics for existing and evolving CR systems.

Entities:  

Mesh:

Year:  2010        PMID: 20199915      PMCID: PMC5228607          DOI: 10.1109/TMI.2009.2036995

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  52 in total

1.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

Review 2.  The physics of computed radiography.

Authors:  J A Rowlands
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

3.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

4.  An image quality comparison of standard and dual-side read CR systems for pediatric radiology.

Authors:  P Monnin; Z Holzer; R Wolf; U Neitzel; P Vock; F Gudinchet; F R Verdun
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

5.  Comparison of imaging properties of a computed radiography system and screen-film systems.

Authors:  S Sanada; K Doi; X W Xu; F F Yin; M L Giger; H MacMahon
Journal:  Med Phys       Date:  1991 May-Jun       Impact factor: 4.071

6.  Dose response of BaFBrl: Eu2+ storage phosphor plates exposed to megavoltage photon beams.

Authors:  H Harold Li; Albin L Gonzalez; Huaying Ji; Dennis M Duggan
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

7.  A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

Authors:  S M Kengyelics; A G Davies; A R Cowen
Journal:  Med Phys       Date:  1998-11       Impact factor: 4.071

Review 8.  Transfer function analysis of radiographic imaging systems.

Authors:  C E Metz; K Doi
Journal:  Phys Med Biol       Date:  1979-11       Impact factor: 3.609

9.  Computed radiography utilizing scanning laser stimulated luminescence.

Authors:  M Sonoda; M Takano; J Miyahara; H Kato
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

10.  Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography.

Authors:  Klaus Bacher; Peter Smeets; Kris Bonnarens; An De Hauwere; Koenraad Verstraete; Hubert Thierens
Journal:  AJR Am J Roentgenol       Date:  2003-10       Impact factor: 3.959

View more
  1 in total

1.  Emerging Breast Imaging Technologies on the Horizon.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Semin Ultrasound CT MR       Date:  2017-09-13       Impact factor: 1.875