Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty.

E Morscher, A Schmassmann.   

Abstract

Entities:  

Mesh:

Year:  1983        PMID: 6847350     DOI: 10.1007/bf00433274

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


× No keyword cloud information.
  31 in total

1.  [Coxarthrosis. b) 10-year results with total hip endoprosthesis].

Authors:  A Lehmann
Journal:  Orthopade       Date:  1979-01       Impact factor: 1.087

2.  Factors in the mechanical failure of the femoral component in total hip prosthesis. Report of six fatigue fractures of the femoral stem and results of experimental loading tests.

Authors:  M Martens; E Aernoudt; P de Meester; P Ducheyne; J C Mulier; R de Langh; P Kestelijn
Journal:  Acta Orthop Scand       Date:  1974

3.  A radiographic analysis of 166 Charnley-Müller total hip arthroplasties.

Authors:  P Cotterill; G A Hunter; M Tile
Journal:  Clin Orthop Relat Res       Date:  1982-03       Impact factor: 4.176

4.  Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures.

Authors:  R Huiskes
Journal:  Acta Orthop Scand Suppl       Date:  1980

5.  An analysis of 119 loosenings in total hip endoprostheses.

Authors:  P Bösch; H Kristen; K Zweymüller
Journal:  Arch Orthop Trauma Surg       Date:  1980

6.  Clinical and radiological long-term results after Charnley-Müller total hip replacement. A 5 to 10 year follow-up study with special reference to aseptic loosening.

Authors:  S S Olsson; A Jernberger; D Tryggö
Journal:  Acta Orthop Scand       Date:  1981-10

7.  Revisional total hip replacement for failed ring arthroplasty.

Authors:  J M Jones
Journal:  J Bone Joint Surg Am       Date:  1979-10       Impact factor: 5.284

8.  Femoral stem failure in total hip replacement.

Authors:  D K Collis
Journal:  J Bone Joint Surg Am       Date:  1977-12       Impact factor: 5.284

9.  Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases.

Authors:  E Y Chao; M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1981-09       Impact factor: 5.284

10.  Dislocation following total hip replacement.

Authors:  M A Ali Khan; P H Brakenbury; I S Reynolds
Journal:  J Bone Joint Surg Br       Date:  1981
View more
  13 in total

1.  Ring uncemented plastic on metal hip replacements--results from an independent unit.

Authors:  D W Mok; K M Bryant
Journal:  J R Soc Med       Date:  1989-03       Impact factor: 5.344

2.  Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  J Wilson-MacDonald; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

3.  [Results of cement-free implanted, Robert Mathys isoelastic acetabular cup].

Authors:  L C Olivier; F Neudeck; C Hippel; S Kaiser; K P Schmit-Neuerburg
Journal:  Unfallchirurgie       Date:  1998-04

4.  Long-term results and survivorship of the McKee-Farrar total hip prosthesis.

Authors:  T Visuri
Journal:  Arch Orthop Trauma Surg       Date:  1987

5.  Survival analysis of an uncemented ceramic acetabular component in total hip replacement.

Authors:  K Knahr; M Böhler; P Frank; H Plenk; M Salzer
Journal:  Arch Orthop Trauma Surg       Date:  1987

6.  Cementless acetabular replacement using a pegged polyethylene prosthesis.

Authors:  K C Bertin; M A Freeman; E Morscher; A Oeri; P A Ring
Journal:  Arch Orthop Trauma Surg       Date:  1985

7.  Total hip replacement with solid autologous femoral head graft for hip dysplasia.

Authors:  B Hintermann; E W Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

8.  Bone reaction to uncemented threaded polyethylene acetabular components.

Authors:  J Krugluger; R Eyb
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

9.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

10.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.