Literature DB >> 3435237

Long-term results and survivorship of the McKee-Farrar total hip prosthesis.

T Visuri1.   

Abstract

Five hundred and eleven McKee-Farrar prostheses implanted at the Orthopedic Hospital of the Invalid Foundation (Helsinki, Finland) between 1967 and 1973 were analyzed for long-term survivorship, clinical results, and the risk factors leading to aseptic loosening of the prosthesis. Reoperation was necessary for aseptic loosening of 91 prostheses and for septic loosening of 19 prosthesis. Ten-year survivorship was 76% and the annual failure rate 2.3%. The failure rate correlated with time. Acetabular cup loosening occurred 1.2 times more often than stem loosening. The retained prostheses remained clinically stable with respect to pain and mobility, but some deterioration was observed in walking ability. In addition to the follow-up period, prosthetic design, right-sided prosthesis, and lengthening of the operated leg proved to be significant factors for aseptic loosening in multiple stepwise regression analysis. After exclusion of the unmeasured leg length inequalities, the lengthening of the operated leg proved to be the most important factor explaining aseptic loosening of the prosthesis. Surgeon's inexperience, operation time, post-traumatic coxarthrosis, and previous operations were correlated to aseptic loosening of the prosthesis.

Entities:  

Mesh:

Year:  1987        PMID: 3435237     DOI: 10.1007/BF00456872

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  34 in total

1.  Experience with the McKee-Farrar total hip replacement. A report of 143 operations.

Authors:  P Salenius; L E Laurent
Journal:  Acta Orthop Scand       Date:  1973

2.  Factors leading to rearthroplasty in a material with radiographically loose total hip prostheses.

Authors:  C Hierton; G Blomgren; U Lindgren
Journal:  Acta Orthop Scand       Date:  1983-08

3.  Total hip replacement: a ten-year follow-up of an early series.

Authors:  B Almby; T Hierton
Journal:  Acta Orthop Scand       Date:  1982-06

4.  An analysis of 119 loosenings in total hip endoprostheses.

Authors:  P Bösch; H Kristen; K Zweymüller
Journal:  Arch Orthop Trauma Surg       Date:  1980

5.  Survivorship of total hip replacements.

Authors:  H S Dobbs
Journal:  J Bone Joint Surg Br       Date:  1980-05

6.  Migration of the femoral stem in hip arthroplasties. Analysis of associations with structural, radiological and follow-up variables.

Authors:  O Söreide; J Lillestöl; A Alho; K Hvidsten
Journal:  Acta Orthop Scand       Date:  1982-04

7.  Ten-year follow-up of Müller hip replacements.

Authors:  O Reikerås
Journal:  Acta Orthop Scand       Date:  1982-12

8.  Replacement of arthritic hips by the McKee-Farrar prosthesis.

Authors:  G K McKee; J Watson-Farrar
Journal:  J Bone Joint Surg Br       Date:  1966-05

9.  Functional evaluation of total hip arthroplasty with five- to ten-year follow-up evaluation.

Authors:  T Perrin; L D Dorr; J Perry; J Gronley; D B Hull
Journal:  Clin Orthop Relat Res       Date:  1985-05       Impact factor: 4.176

10.  Clinical experience with Mueller total hip endoprostheses of different design and material.

Authors:  H G Willert; U Buchhorn; L Zichner
Journal:  Arch Orthop Trauma Surg       Date:  1980
View more
  1 in total

1.  Total hip arthroplasty: leg length inequality impairs functional outcomes and patient satisfaction.

Authors:  Christoph Röder; Raphael Vogel; Lukas Burri; Daniel Dietrich; Lukas P Staub
Journal:  BMC Musculoskelet Disord       Date:  2012-06-11       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.