Literature DB >> 2539475

Ring uncemented plastic on metal hip replacements--results from an independent unit.

D W Mok1, K M Bryant.   

Abstract

We present 251 Ring uncemented plastic on metal (UPM) hip replacements with a follow-up of 2-5 years. Judging the functional results by the Harris hip evaluation for the surviving 234 hips, 79.8% were good to excellent, 11.7% fair, and 8.5% poor at an average of 3 years. The mortality within one month of surgery was 0.79%. There were 4 cases of deep infection (1.59%), 3 of which required excision arthroplasty. At 3 years, 6 hips (2.39%) had required revision, all for aseptic femoral loosening, 2 of which also had acetabular loosening. Ring UPM hip is both safe and reliable in the hands of many surgeons outside Ring's unit.

Entities:  

Mesh:

Year:  1989        PMID: 2539475      PMCID: PMC1292037          DOI: 10.1177/014107688908200309

Source DB:  PubMed          Journal:  J R Soc Med        ISSN: 0141-0768            Impact factor:   5.344


  13 in total

1.  Ring uncemented hip replacements. The results of revision.

Authors:  M Patterson
Journal:  J Bone Joint Surg Br       Date:  1987-05

2.  The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases.

Authors:  T A Andrew; J P Flanagan; M Gerundini; R Bombelli
Journal:  Clin Orthop Relat Res       Date:  1986-05       Impact factor: 4.176

3.  Complete replacement arthroplasty of the hip by the ring prosthesis.

Authors:  P A Ring
Journal:  J Bone Joint Surg Br       Date:  1968-11

4.  Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty.

Authors:  E Morscher; A Schmassmann
Journal:  Arch Orthop Trauma Surg       Date:  1983

5.  Survivorship of total hip replacements.

Authors:  H S Dobbs
Journal:  J Bone Joint Surg Br       Date:  1980-05

6.  Five to fourteen year interim results of uncemented total hip arthroplasty.

Authors:  P A Ring
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

7.  The UCLA Charnley experience: a long-term follow-up study using survival analysis.

Authors:  R H Jinnah; H C Amstutz; S M Tooke; F Dorey; T Dalseth
Journal:  Clin Orthop Relat Res       Date:  1986-10       Impact factor: 4.176

8.  Ring UPM total hip arthroplasty.

Authors:  P A Ring
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

9.  The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.

Authors:  G Lord; P Bancel
Journal:  Clin Orthop Relat Res       Date:  1983-06       Impact factor: 4.176

10.  Uncemented total hip replacement.

Authors:  W Groher
Journal:  Can J Surg       Date:  1983-11       Impact factor: 2.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.