Literature DB >> 6828740

Artifacts produced by moving grids.

D R Bednarek, S Rudin, R Wong.   

Abstract

Anti-scatter grids reduce the amount of secondary radiation contributing to the image and improve the signal-to-noise ratio. However, they may also lead to the creation of linear artifacts representing the shadows of the radiopaque septa. Grid motion perpendicular to the septa during the exposure can cause blurring of the artifacts; however, the wider septa of recently proposed grids increase the difficulty of suppressing the artifacts entirely. Physical characteristics which affect perceptibility of grid-line artifacts and the conditions needed for their elimination are analyzed. Sufficient grid movement can eliminate overlap artifacts, while synchronization of linear grid motion with exposure time can suppress artifacts for relatively small grid movements.

Mesh:

Year:  1983        PMID: 6828740     DOI: 10.1148/radiology.147.1.6828740

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Design and evaluation of a grid reciprocation scheme for use in digital breast tomosynthesis.

Authors:  Tushita Patel; Helen Sporkin; Heather Peppard; Mark B Williams
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

2.  Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors.

Authors:  R Rana; V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

3.  Real time implementation of anti-scatter grid artifact elimination method for high resolution x-ray imaging CMOS detectors using Graphics Processing Units (GPUs).

Authors:  R Rana; S V Setlur Nagesh; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

4.  Scatter estimation and removal of anti-scatter grid-line artifacts from anthropomorphic head phantom images taken with a high resolution image detector.

Authors:  R Rana; A Jain; A Shankar; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-31

5.  Limitations of anti-scatter grids when used with high resolution image detectors.

Authors:  V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

6.  Patch Based Grid Artifact Suppressing in Digital Mammography.

Authors:  Qingqing Ling; Shuyu Wu; Xiaoman Duan; Genggeng Qin; Jianhui Ma; Chaomin Chen; Hongliang Qi; Linghong Zhou; Yuan Xu
Journal:  Biomed Res Int       Date:  2018-08-12       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.