Literature DB >> 6508716

Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressure.

G P Molhoek, K H Wesseling, J J Settels, E van Vollenhoven, H W Weeda, B de Wit, A C Arntzenius.   

Abstract

Blood pressure in the finger was measured by a servo-plethysmomanometer constructed after the design of Penàz, which uses the principle of the unloaded arterial wall. The device contains a photoelectric plethysmograph mounted in an inflatable cuff and an electro-pneumatic transducer to control air pressure in the cuff via a servosystem. Comparison of simultaneous measurements of intra-arterial pressure in the brachial artery was performed on 33 patients suspected of having hypertension. In 12 patients evaluation of the technique could not be carried out due to technical failures or distorted blood pressure wave forms. Results of the remaining 21 patients show a mean underestimation of intra-arterial blood pressure by finger cuff blood pressure of 0.8 kPa (6 mm Hg), both for systolic and diastolic levels. The scatter range of the difference is from 1.9 to -3.5 kPa for systolic and 0.1 to -2.5 kPa for diastolic values. It appears that, although not all technical problems are solved, the Penàz servo-plethysmo-manometer is potentially an elegant method by which to arrive at the fully calibrated wave form of blood pressure in a finger in a non-invasive and continuous fashion.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6508716     DOI: 10.1007/bf01910489

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  10 in total

1.  A SPHYGMOMANOMETER FOR EPIDEMIOLOGISTS.

Authors:  G A ROSE; W W HOLLAND; E A CROWLEY
Journal:  Lancet       Date:  1964-02-08       Impact factor: 79.321

2.  Blood pressure measuring methods.

Authors:  H W SHIRER
Journal:  Ire Trans Biomed Electron       Date:  1962-04

3.  [Contribution to the continuous indirect blood pressure measurement].

Authors:  J Penáz; A Voigt; W Teichmann
Journal:  Z Gesamte Inn Med       Date:  1976-12-15

4.  Assessment of arterial obstruction in vessels supplying the fingers by measurement of local blood pressures and the skin temperature response test--correlation with angiographic evidence.

Authors:  A R Downs; P Gaskell; I Morrow; C L Munson
Journal:  Surgery       Date:  1975-04       Impact factor: 3.982

5.  Noninvasive measurements of digital arterial pressure and compliance in man.

Authors:  R Nakayama; T Azuma
Journal:  Am J Physiol       Date:  1977-07

6.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1.

Authors:  J A Posey; L A Geddes; H Williams; A G Moore
Journal:  Cardiovasc Res Cent Bull       Date:  1969 Jul-Sep

7.  Pressure wave transmission along the human aorta. Changes with age and in arterial degenerative disease.

Authors:  M F O'Rourke; J V Blazek; C L Morreels; L J Krovetz
Journal:  Circ Res       Date:  1968-10       Impact factor: 17.367

8.  Regional variation of series elasticity in canine arterial smooth muscles.

Authors:  R H Cox
Journal:  Am J Physiol       Date:  1978-05

9.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.

Authors:  G W Mauck; C R Smith; L A Geddes; J D Bourland
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

10.  Measurement of digital blood pressure after local cooling.

Authors:  S L Nielsen; N A Lassen
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-11
  10 in total
  30 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

2.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

3.  Venous responses to rhythmic exercise in contralateral forearm and calf.

Authors:  D A Duprez; M De Buyzere; J M De Sutter; S A Deman; N Y De Pue; D L Clement
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

4.  Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.

Authors:  R H Epstein; S Huffnagle; R R Bartkowski
Journal:  J Clin Monit       Date:  1991-04

5.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

6.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

7.  Reliability of blood pressure determination with the Finapres with altered physiological states or pharmacodynamic conditions.

Authors:  D McAuley; B Silke; S Farrell
Journal:  Clin Auton Res       Date:  1997-08       Impact factor: 4.435

8.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

9.  Pharmacokinetic-pharmacodynamic modelling of oxprenolol in man using continuous non-invasive blood pressure monitoring.

Authors:  R Koopmans; B Oosterhuis; J M Karemaker; J Wemer; C J van Boxtel
Journal:  Eur J Clin Pharmacol       Date:  1988       Impact factor: 2.953

10.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.