Noninvasive measurements of digital arterial pressure and compliance in man.

R Nakayama, T Azuma.   

Abstract

A noninvasive method was developed for measuring the digital arterial pressure and the compliance by using a fingertip pneumoplethysmograph and a pneumatic cuff. The compliance (C) of the digital artery was obtained from the peak amplitude of the volume pulse wave (deltaVp-a) under the effect of the cuff pressure (Po-a) by the equation: C = deltavp-a/(Ps - P-o-a) during the dicrotic phase defined in this study. The normal mean value was 11.37 +/- 0.59 X 10(-5) cm3/mmHg. On lowering of the cuff pressure, the moment when the deltaVp value becomes positive is regarded as the systolic pressure (Ps). At the end of the dicrotic phase, the mean amplitude (deltaVss') of the pulse wave during one pulse cycle (SS') and the ratios (deltaVss'/deltaVsd), where deltaVsd is the mean amplitude of the wave during the systolic period (SD), of successive waves after a particular wave fail to increase at the same rate when the cuff pressure decreased below the diastolic pressure. The cuff pressure corresponding to this particular wave is regarded as the diastolic pressure (Pd). The mean value of the mean digital pressure of normotensive subjects was 80.6 +/- 1.2 mmHg.

Entities:  

Mesh:

Year:  1977        PMID: 879333     DOI: 10.1152/ajpheart.1977.233.1.H168

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  7 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

2.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

Authors:  H Shimazu; A Kawarada; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

3.  Noninvasive measurement of arterial elasticity in various human limbs.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

4.  Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressure.

Authors:  G P Molhoek; K H Wesseling; J J Settels; E van Vollenhoven; H W Weeda; B de Wit; A C Arntzenius
Journal:  Basic Res Cardiol       Date:  1984 Sep-Oct       Impact factor: 17.165

5.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01

6.  Noninvasive measurement of elastic properties in human finger arteries: clinical data comparing blood pressure and funduscopic examination.

Authors:  K Seki
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

7.  A vibration-based approach to quantifying the dynamic elastance of the superficial arterial wall.

Authors:  Jia-Jung Wang; Shing-Hong Liu; Hung-Mao Su; Steven Chang; Wei-Kung Tseng
Journal:  Biomed Eng Online       Date:  2016-04-16       Impact factor: 2.819

  7 in total